Journal: :iranian journal of radiation research 0
a. saravanakumar department of applied science, psg college of technology, coimbatore 641 004, india k. vaideki 1department of applied science, psg college of technology, coimbatore 641 004, india k.n. govindarajan department of radiology, psg institute of medical science and research & hospitals, coimbatore 641004, india b. devanand department of radiology, psg institute of medical science and research & hospitals, coimbatore 641004, india s. jayakumar department of physics, psg institute of technology and applied research, coimbatore 641 062, india s.d. sharma radiological physics and advisory division, bhabha atomic research centre, mumbai- 400094, india

background: to suggest south india ct diagnostic reference levels (drls) by collecting radiation doses for the most commonly performed ct examinations. materials and methods: a pilot study investigated the most frequent ct examinations. 110 ct sites were asked to complete a survey booklet to allow the recording of ct parameters for each of 3 ct examinations during a 1 year time period. dose dat...

2014
Miyuki Takasu Takuji Yamagami Yuko Nakamura Daisuke Komoto Yoko Kaichi Chihiro Tani Shuji Date Masao Kiguchi Kazuo Awai Joseph P. R. O. Orgel

PURPOSE It is well recognized that therapeutic irradiation can result in bone damage. However, long-term bone toxicity associated with computed tomography (CT) performed during interventional angiography has received little attention. The purpose of this study was to determine the prevalence of osteoporosis and trabecular microstructural changes in patients after transarterial chemoembolization...

Journal: :journal of paramedical sciences 0
daryoush khoramian department of medical physics, faculty of medicine, tarbiat modares university, tehran, iran. soroush sistani department of medical physics, semnan university of medical sciences, semnan, iran.

primary and widely in use computed tomography (ct) dose descriptor is a volumetric ct dose index (ctdiv) that is usually measured by a pencil ionization chamber with active length of 100mm and polymethyl methacrylate (pmma) phantom. ctdiv depends on scan parameters such as mas, kv, collimation, tube rotation time but is independent of patient’s size and shape. for the purpose of a good estimati...

شریفی, ساناز, ورشوساز, مسعود,

Background: Paranasal sinus disease is one of the most common problems of patients that refer to ENT centers. Adding to clinical examination imaging plays an important role in diagnosis and treatment. Also the imaging of paranasal sinuses is necessary before surgery. Although computed tomography is the modality of choice for these areas, it has some disadvantages which the most important one is...

A. Saravanakumar, B. Devanand, K. Vaideki, K.N. Govindarajan, S. Jayakumar, S.D. Sharma,

Background: To suggest South India CT diagnostic reference levels (DRLs) by collecting radiation doses for the most commonly performed CT examinations. Materials and Methods: A pilot study investigated the most frequent CT examinations. 110 CT sites were asked to complete a survey booklet to allow the recording of CT parameters for each of 3 CT examinations during a 1 year time period. Dose...

Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...

Journal: :journal of biomedical physics and engineering 0
a janbabanezhad-toori school of medicine, babol university of medical sciences, babol, iran a shabestani-monfared department of medical physics, faculty of medicine, babol university of medical sciences, babol, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی بابل (babol university of medical sciences) m r deevband department of medical physics, school of medicine, shahid beheshti university of medical sciences, tehran, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی بابل (babol university of medical sciences) r abdi department of radiology, mazandaran university of medical sciences, sari, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی شهید بهشتی (shahid beheshti university of medical sciences) m nabahati department of radiology, babol university of medical sciences, babol, iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی مازندران (mazandaran university of medical sciences)

background : medical x-rays are the largest man-made source of public exposure to ionizing radiation. while the benefits of computed tomography (ct) are well known in accurate diagnosis, those benefits are not risk-free. ct is a device with higher patient dose in comparison with other conventional radiation procedures. objective: this study is aimed at evaluating radiation dose to patients from...

Journal: :Atom Indonesia 2021

During Computed Tomography (CT) scan examinations, it is important to ensure a good diagnosis by providing the maximum information detect pathologies and this can be done with reduced dose. In respect, several methods of dose reduction have been studied evaluated. This work investigates effect tube voltage while varying current on image quality radiation at Chest CT examination. study was condu...

Journal: :iranian journal of medical physics 0
peyman hejazi medical physics dept., semnan university of medical sciences, semnan, iran

introduction in computed tomography (ct) technology, an optimal radiation dose can be achieved via changing radiation parameters such as ma, pitch factor, rotation time and tube voltage (kvp) for diagnostic images. materials and methods in this study, the brain, abdomen, and thorax scaning was performed using toshiba 16-slice scannerand standard aapm and ctdi phantoms. aapm phantom was used for...

Journal: :iranian journal of radiology 0
chih-chen chang department of medical imaging and intervention, chang gung memorial hospital, chang gung university, linkou, taiwan yon-cheong wong department of medical imaging and intervention, chang gung memorial hospital, chang gung university, linkou, taiwan; department of medical imaging and intervention, chang gung memorial hospital, chang gung university, linkou, taiwan cheng-hsien wu department of medical imaging and intervention, chang gung memorial hospital, chang gung university, linkou, taiwan huan-wu chen department of medical imaging and intervention, chang gung memorial hospital, chang gung university, linkou, taiwan li-jen wang department of medical imaging and intervention, chang gung memorial hospital, chang gung university, linkou, taiwan yu-hsien lee department of medical imaging and intervention, chang gung memorial hospital, chang gung university, linkou, taiwan

conclusion attending radiologists could diagnose acute appendicitis accurately on ne-ldct. performance of senior residents on ne-ldct is better than junior residents and comparable to attending radiologists. results diagnostic performances for acute appendicitis were not statistically different for attending radiologists at both examinations. better performance was noted on the ce-sdct with a b...