نتایج جستجو برای: viscous Damper System Damper Configuration Tabas Earthquake ANSYS Dynamic Response

تعداد نتایج: 3428758  

In this study, the effects of three different viscous damper configurations, chevron, diagonal and toggle, as well as brace stiffness on the performance of brace-viscous damper system in various steel frams under different earthquake records were investigated. A finite element software, ANSYS, is exploited to develop the numerical models. To verify the numerical simulations, their results were ...

Journal: :journal of structural engineering and geo-techniques 2012
f. barati a. esfandiari

in this paper, seismic behavior of the existing buildings equipped by friction dampers is studied. seismic performance of6-story, 9-story and 12-story steel buildings with damper and without damper were studied. the finite element modeling technique (sap2000 software) is used for analysis. time history analyzing was done to achieve this purpose. for nonlinear dynamic analysis, the responses of ...

ژورنال: مهندسی دریا 2016

In the present paper, the effectiveness of Tuned Liquid Damper (TLD) in controlling the dynamic responses of offshore jacket platforms under earthquake excitation is investigated. This type of dampers consisting of one or more fluid (generally water) containers can be installed on the platform’s deck. Hydrodynamic actions induced by the tilting of the water surface in the container act as...

A. Esfandiari, F. Barati

In this paper, seismic behavior of the existing buildings equipped by friction dampers is studied. Seismic performance of6-story, 9-story and 12-story steel buildings with damper and without damper were studied. The finite element modeling technique (SAP2000 Software) is used for analysis. Time History analyzing was done to achieve this purpose. For nonlinear dynamic analysis, the responses of ...

Mohammad Ali Jafari, Nasser Gholaman

Using energy absorption systems in the structures with malfunctioning components is of paramount importance. By absorbing the seismic energy, these systems help the components of the structure to remain resilient during earthquake. In the present study, viscous dampers were applied in order to enhance the reactions of tall building with belt truss. To assess the response of a structure under e...

Mohammad Ali Jafari, Nasser Gholaman

Using energy absorption systems in the structures with malfunctioning components is of paramount importance. By absorbing the seismic energy, these systems help the components of the structure to remain resilient during earthquake. In the present study, viscous dampers were applied in order to enhance the reactions of tall building with belt truss. To assess the response of a structure un...

2009
F. Hejazi J. Noorzaei M. S. Jaafar A. A. Abang

This paper describes the development of a numerical finite element algorithm used for the analysis of reinforced concrete structure equipped with shakes energy absorbing device subjected to earthquake excitation. For this purpose a finite element program code for analysis of reinforced concrete frame buildings is developed. The performance of developed program code is evaluated by analyzing of ...

2001
G. YANG H. J. JUNG

Magnetorheological (MR) dampers are one of the most promising new devices for structural vibration reduction. Because of their mechanical simplicity, high dynamic range, low power requirements, large force capacity, and robustness, these devices have been shown to mesh well with application demands and constraints to offer an attractive means of protecting civil infrastructure systems against s...

2001
Hideo FUJITANI Hiroshi SODEYAMA Katsuhiko Hata Yutaka Komatsu Norio IWATA Katsuaki SUNAKODA

Magneto-rheological damper (MR damper) has been expected to control the response of civil and building structures in recent years, because of its large force capacity and controllable force characteristics. Recent study is to the application of controllable dampers for reducing earthquake response of buildings and/or wind induced sway. The dynamic characteristics of the MR damper have to be cla...

A. Kheyrodin, M. Gerami, M. R. Hashemi, R. Vahdani,

Dampers can reduce structural response under dynamic loads. Since dampers are costly, the design of structures equipped with dampers should make their application economically justifiable. Among the effective cost reduction factors is optimal damper placement. Hence, this study intended to find the optimal viscous damper placement using efficient optimization methods. Taking into account the no...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید