a. ataei m.h. panjeshahi m. gharaie n. tahouni

temperature restrictions on aqueous effluents dictate that streams with a temperature higher than the permitted level needed to pass through cooling systems to reduce the effluent temperature before discharge. in this study, by considering the grouping design rules based on pinch technology, an optimum design for a distributed effluent cooling system, has been developed. a counter-flow wet cool...

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2010
mohammad hassan panjeshahi abtin ataei mona gharaie

the present paper describes the designing of a thermally and economically optimum mechanical draft counter-flow wet cooling tower. the design model allows the use of a variety of packing materials in the cooling tower toward optimizing heat transfer. once the optimum packing type is chosen, a compact cooling tower with low fan power consumption is modelled within the known design variables. mor...

Abtin Ataei, Mohammad Hassan Panjeshahi Mona Gharaie

The present paper describes the designing of a thermally and economically optimum mechanical draft counter-flow wet cooling tower. The design model allows the use of a variety of packing materials in the cooling tower toward optimizing heat transfer. Once the optimum packing type is chosen, a compact cooling tower with low fan power consumption is modelled within the known design variables....

Journal: :international journal of architectural engineering and urban planning 0
mohammadjavad mahdavinejad tarbiat modares university, tehran, iran mohammadhossein ghasempoorabadi honar university kavan javanrudi tarbiat modares university, tehran, iran

this paper is an attempt to numerical modeling and experimental study of air flow in the yazdi wind-towers. wind towers has been known as one of the most effective climatic elements in iranian traditional architecture. this paper is an attempt to evaluating yazdi wind-tower to discussion the two main questions: 1. what is the role of orientation of wind-towers span, regarding to climate and hei...

Kavan Javanrudi, Mohammadhossein Ghasempoorabadi, Mohammadjavad Mahdavinejad,

This paper is an attempt to Numerical Modeling and Experimental Study of Air Flow in the Yazdi Wind-Towers. Wind Towers has been known as one of the most effective climatic elements in Iranian traditional architecture. This paper is an attempt to evaluating Yazdi wind-tower to discussion the two main questions: 1. What is the role of Orientation of wind-towers span, regarding to climate and he...

and G. A. Iravani, H. Ahmadikia,

Design of a natural dry cooling tower has been accomplished in two sections: the design of heat exchangers and the numerical solution of flow through the tower. Heat exchanger (Heller type) has been simulated thermodynamically and then coupled with a computer program, which calculated the turbulent natural convection flow through the tower. The computer program developed for this purpose can be...

2006
John Gianni

In this paper, we present a concrete proof point, achieved after roughly two years of collaborative effort, resulting in substantially decreased time-to-silicon and improved semiconductor customer success. We describe a foundry package containing a unique Cadence evaluation test chip, available today, and fabricated using the 0.18um CMOS Tower Semiconductor process design kit, Tower standard-ce...

Journal: :international journal of advanced design and manufacturing technology 0
navid bozorgan nariman bozorgan

a thermodynamic analysis of the counter flow wet cooling tower (cwct) in the steelmaking unit of the khuzestan steel company (ksc) is performed in this paper. we evaluated both energy and exergy formulations for analyzing the heat and mass transfer, exergy and second-law efficiency in this cooling tower. the lewis factor le f is an indication of the relative rates of heat and mass transfer in a...

and G. A. Iravani, H. Ahmadikia,

Design of a natural dry cooling tower has been accomplished in two sections: the design of heat exchangers and the numerical solution of flow through the tower. Heat exchanger (Heller type) has been simulated thermodynamically and then coupled with a computer program, which calculated the turbulent natural convection flow through the tower. The computer program developed for this purpose can be...

2012
Pingsheng Bridge Sanchaji Bridge Wanxin Bridge Jiangdong Bridge Liede Bridge Nanjijiang Xinzhou Bridge

The cable tower of Liede Bridge is a double-column curved-lever arched-beam portal framed structure. Being novel and unique in structure, its cable tower differs in complexity from traditional ones. This paper analyzes the ultimate load capacity of cable tower by adopting the finite element calculations and model tests which indicate that constitutive relations applied here give a better simula...