نتایج جستجو برای: surface plasmon resonance (spr)

تعداد نتایج: 836457  

Journal: :iranian chemical communication 0
professor mohammad ali karimi department of chemistry, payame noor university, p.o. box 19395-4697, tehran, iran malihe alsadat mozaheb department of chemistry, payame noor university, p.o. box 19395-4697, tehran, iran abdolhamid hatefi-mehrjardi department of chemistry, payame noor university, p.o. box 19395-4697, tehran, iran hossein tavallali department of chemistry, payame noor university, p.o. box 19395-4697, tehran, iran abdol mohammad attaran department of chemistry, payame noor university, p.o. box 19395-4697, tehran, iran

in this paper, multivariate calibration methods of partial least squares (pls) and principle component regression (pcr) were investigated in simultaneously determination of hydrazine (hz) and acetylhydrazine (ahz). the aforementioned methods are based on formation of the silver nanoparticles (agnps) from the reaction of hz and ahz with ag+ ions as oxidizing agent in the presence of citrate ions...

بهرامپور, علیرضا, تجلی, حبیب, شریفی, مریم, پاشایی عدل, حمید,

In recent years, development of highly sensitive biosensors is the main purpose of researchers to diagnose and prevent diseases. Accordingly, in this paper, surface plasmon resonance (SPR) biosensor has been designed based on one dimensional layered structures. With regard to the fact that the quality of SPR sensors strongly depends on the reflectance amplitude and full width at half maximum (F...

Journal: :international journal of optics and photonics 0
jalil jafari no. 444, prof. yousef sobouti blvd. p. o. box 45195-1159 zanjan iran rahman nouroozi no. 444, prof. yousef sobouti blvd. p. o. box 45195-1159 zanjan iran

for a fiber optical surface plasmon resonance (spr) sensor a short part of its cladding should be removed to coat a thin layer of a metal. usually this is problematic when an optical fiber with small core diameter is used. in this paper, a new method using µliter droplet of the hf acid for short fiber optical taper fabrication is reported. using this method in a multi-mode optical fiber with th...

Journal: :Analytical and bioanalytical chemistry 2003
Jirí Homola

Surface plasmon resonance (SPR) biosensors are optical sensors exploiting special electromagnetic waves-surface plasmon-polaritons-to probe interactions between an analyte in solution and a biomolecular recognition element immobilized on the SPR sensor surface. Major application areas include detection of biological analytes and analysis of biomolecular interactions where SPR biosensors provide...

2012
Volodymyr Chegel

The computer modeling is carried out for parameter of sensitivity of optoelectronic chemical and biosensors, using phenomena of surface plasmon resonance (SPR). The physical model of SPR-sensor’s is described with (or without) of modifications of sensitive gold film surface by a dielectric layer. The variants of increasing of sensitivity for SPR-biosensors, constructed on the principle gold – d...

2014
Régis Méjard Benjamin Thierry Christof Markus Aegerter

The objectives of this study were to establish an in-depth understanding of the signals induced by mammalian cells in surface plasmon resonance (SPR) sensing. To this end, two plasmonic structures with different propagation and penetration distances were used: conventional surface plasmon resonance and long-range surface plasmon resonance. Long-range SPR showed a lesser sensitivity to the absol...

2016
Da-Shin Wang Shih-Kang Fan

Surface plasmon resonance (SPR) is a label-free, highly-sensitive, and real-time sensing technique. Conventional SPR sensors, which involve a planar thin gold film, have been widely exploited in biosensing; various miniaturized formats have been devised for portability purposes. Another type of SPR sensor which utilizes localized SPR (LSPR), is based on metal nanostructures with surface plasmon...

2015
Hoang Hiep Nguyen Jeho Park Sebyung Kang Moonil Kim

Surface plasmon resonance (SPR) is a label-free detection method which has emerged during the last two decades as a suitable and reliable platform in clinical analysis for biomolecular interactions. The technique makes it possible to measure interactions in real-time with high sensitivity and without the need of labels. This review article discusses a wide range of applications in optical-based...

Journal: :Applied optics 2008
Mohamed Nakkach Pierre Lecaruyer Fabrice Bardin Jaouhar Sakly Zohra Ben Lakhdar Michael Canva

Surface plasmon resonance (SPR) sensing is an optical technique that allows real time detection of small changes in the physical properties, in particular in the refractive index, of a dielectric medium near a metal film surface. One way to increase the SPR signal shift is then to incorporate a substance possessing a strong dispersive refractive index in the range of the plasmon resonance band....

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید