Journal: :Thorax 1991
S P Newman A W Weisz N Talaee S W Clarke

BACKGROUND The metered dose inhaler is difficult to use correctly, synchronising actuation with inhalation being the most important problem. A breath actuated pressurised inhaler, designed to help patients with poor inhaler technique, was compared with a conventional metered dose inhaler in terms of aerosol deposition and bronchodilator response. METHODS Radioaerosol deposition and bronchodilat...

Journal: :iranian journal of allergy, asthma and immunology 0
sanaz tavasoli hassan heidarnazhad anooshiravan kazemnejad

asthma affects an estimated 300 million people worldwide. poor compliance with the prescribed medication leads to increased mortality and morbidity. various determinants of compliance have been described. the purpose of this study was to determine factors that can influence patients' compliance with prescribed metered dose inhaler drugs. 179 patients with diagnosis of asthma were selected from ...

2016

PRODUCT DESCRIPTION Salmeterol + Fluticasone propionate (Seretide) 25/50mcg Metered Dose Inhaler: Each single actuation provides salmeterol xinafoate equivalent to 25mcg of salmeterol and 50mcg of fluticasone propionate. Salmeterol + Fluticasone propionate (Seretide) 25/125mcg Metered Dose Inhaler: Each single actuation provides salmeterol xinafoate equivalent to 25mcg of salmeterol and 125mcg ...

Journal: :Age and ageing 1999
V Jones C Fernandez P Diggory

AIMS To see if elderly people can use the breath-activated (Easi-breathe) and dry powder (Turbohaler) inhalers as effectively as the metered-dose inhaler and Volumatic system. METHODS 102 inhaler-naive patients (aged 75-101, mean 84 years), without cognitive impairment, were randomly allocated one of Easi-breathe, Turbohaler or metered-dose inhaler and Volumatic placebo inhalers. Standardized...

Journal: :BMJ 2001
D Brocklebank J Wright C Cates

OBJECTIVE To determine the clinical effectiveness of pressurised metered dose inhalers (with or without spacer) compared with other hand held inhaler devices for the delivery of corticosteroids in stable asthma. DESIGN Systematic review of randomised controlled trials. DATA SOURCES Cochrane Airways Group trials database (Medline, Embase, Cochrane controlled clinical trials register, and han...

Journal: :Chest 1986
R Olivenstein N Wolkove C Cohen H Frank H Kreisman

Nineteen outpatients with stable obstructive pulmonary disease (mean forced expiratory volume in one second [FEV1], 1.00 + 0.10 L) were evaluated for airway response to albuterol (salbutamol) administered by metered-dose inhaler and Bosch ultrasonic nebulizer (BUSN). Albuterol administered by metered-dose inhaler but not by nebulizer caused a significant increase in FEV1 and the mean forced exp...

Journal: :Thorax 1989
S P Newman A R Clark N Talaee S W Clarke

A radiotracer technique has been used to assess aerosol delivery from a pressurised metered dose inhaler, used both with and without a 10 cm cylindrical spacer attachment (Syncroner), which has an open section in its upper surface. The radionuclide technetium-99m (99mTc) was added to sodium cromoglycate in a canister (Intal inhaler; 1 mg/puff); in vitro studies with a multistage liquid impinger...

Journal: :Archives of Pediatrics & Adolescent Medicine 2001

Journal: :BMJ 2001
H Minnis A McMillan M Gillies S Smith

responses to salbutamol using Diskhaler versus metered-dose inhaler. Comparison of the bronchodilating efficacies of a novel salbutamol metered dose powder inhaler and a pressurised metered dose aerosol with a spacer. Efficacy of a new non-ozone depleting formulation for salbutamol. Comparison of inhaled ter-butaline administered by either the Turbuhaler dry powder or a metered-dose inhaler wit...

Journal: :Psychonomic Science 1969