نتایج جستجو برای: iron removal (water treatment)

تعداد نتایج: 2115692  

M Noori, S Partani, S.S* Mehdizadeh,

Background & objectives: In recent years, iron nanoparticles have been successfully used to remove water pollutants. Fecal coliform is one of the parameters that reduces water quality and its removal is essential. The aim of the present study is using nanoscale zerovalent iron particles to enhance the usual sand filters in removal of fecal coliform of groundwater in Ilam city. Methods: Water s...

2016
Joe Heffron Matt Marhefke Brooke K. Mayer

This study investigated the effects of four operational and environmental variables on the removal of trace metal contaminants from drinking water by electrocoagulation (EC). Removal efficiencies for five metals (arsenic, cadmium, chromium, lead and nickel) were compared under varying combinations of electrode material, post-treatment, water composition and pH. Iron electrodes out-performed alu...

Journal: :jundishapur journal of health sciences 0
afshin takdastan environmental technologies research center, department of environmental health,ahvaz jundishapur university of medical sciences, ahvaz, ir iran saeed emami tabar department of environmental engineering, islamic azad university, khuzestan science and research branch, ahvaz, ir iran abdolkazem neisi department of environmental health, ahvaz jundishapur university of medical sciences, ahvaz, ir iran azadeh eslami department of environmental engineering, college of environment and energy, tehran science and research branch, islamic azad university, tehran, ir iran; department of environmental engineering, college of environment and energy, tehran science and research branch, islamic azad university, tehran, ir iran. tel: +98-9166054619, fax: +98-6113342262

background existence of fluoride in drinking water above the permissible level causes human skeletal fluorosis. objectives electrocoagulation by iron and aluminum electrodes was proposed for removing fluoride from drinking water. materials and methods effects of different operating conditions such as treatment time, initial ph, applied voltage, type and number of electrodes, the spaces between ...

2005
Anastasios I. Zouboulis Ioannis A. Katsoyiannis

The biological treatment of groundwaters is used primarily to remove electron donors from water sources, providing (biologically) stable drinking water, which preclude bacterial regrowth during subsequent water distribution. To the electron donors belong also the dissolved metal cations of ferrous iron and manganese, which are common contaminants found in most (anaerobic) groundwaters. The remo...

ژورنال: طلوع بهداشت یزد 2012
ابوئیان جهرمی, محدثه , احرامپوش, محمد حسن, زارع, حمید رضا, سازواری, مهری , سلمانی ندوشن, محمد حسین, عسکری شاهی, محسن, قانعیان, محمد تقی,

 Background: The primary coolant is an essential cooling medium used to control heat in a nuclear power plant. During the oxidation process, Nickel may be released in the primary coolant which increases its contamination. The operational problems and high cost of treatment necessitate the research for some newer methods. The aim of this research is investigation of nickel removal from synthetic...

Ahmad Reza Yari, Hamed Biglari, Mostafa Alizadeh, Sara Hashemi,

Background & Aims of the Study: Discharge of textile industry colored wastewater without enough treatment into natural water resources cause serious pollution. Most of the conventional wastewater treatment methods are not effective enough to remove these dyes from wastewater. In this study, efficiency of electrocoagulation process with iron electrodes for treatment of Reactive Yellow 14 dye...

The presence of particles such as algae, clay, organic materials and water-soluble substances often create turbidity or color in water. In recent years, electrocoagulation process has attracted an extensive attention due to its advantages. Since sand filters are widely used in water treatment industry and their corresponding backwash water is large in volume, turbidity removal will save water c...

Journal: :jentashapir journal of health research 0
mansooreh dehghani department of environmental health, research center for health sciences, school of health, shiraz university of medical sciences, shiraz, ir iran samaneh shahsavani department of environmental health engineering, school of health, student research committee, shiraz university of medical sciences, shiraz, ir iran; department of environmental health engineering, school of health, student research committee, shiraz university of medical sciences, shiraz, ir iran. tel: +98-9385322369, fax: +98-7137260225 narges shamsedini department of environmental health engineering, school of health, student research committee, shiraz university of medical sciences, shiraz, ir iran mohammad reza javaheri department of environmental health engineering, school of health, student research committee, shiraz university of medical sciences, shiraz, ir iran

conclusions it was shown that the removal efficiency of nitrate was directly proportional to the amount of chaff, temperature, and contact time but inversely to the ph. this study showed that nitrate removal by chaff is a promising technique. results the result of this study revealed that chaff as an absorbent could remove nitrate from solutions, and the efficiency of adsorption increased as co...

Journal: :international archives of health sciences 0
m.b. miranzadeh environmental health engineering department, health faculty, kashan university of medical sciences, kashan, iran m. naderi qotb-e-pavandi avenue, pezeshk boulevard, kashan university of medical sciences, kashan, iran h. akbari biostatistics & public health department, health faculty, kashan university of medical sciences, kashan, iran a. mahvi environmental health engineering department, health faculty, tehran university of medical sciences, tehran, iran v. past environmental health engineering department, health faculty, kashan university of medical sciences, kashan, iran

aims: arsenic contamination of natural water resources has become an important environmental problem in the world. the adsorption method by iron filings adsorbent or zero-valent iron was used. the study aimed to evaluate the efficiency of iron filings in arsenite removal from polluted water and to investigate the effect of magnetic field on the process. materials & methods: this interventional ...

Afshin Ebrahimi, Asrin Pashaee, Ensiyeh Taheri, Mokhtar Mahdavi,

Background & Aims of the Study: Coagulation is an essential process for the removal of fine particulate matter in water treatment. Polyaluminium ferric chloride (PAFC) is a composite inorganic polymer of Aluminium and ferric salt. This study was conducted to find out the optimum coagulation conditions for the removal of turbidity, color and organic matter (UV absorbance) in low to mediu...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید