نتایج جستجو برای: flat panel detector x-ray

تعداد نتایج: 844034  

2006
Uwe Ewert

New digital detectors were developed for medical applications, which have the potential to substitute the X-ray film. Digital Detector Arrays (DDA: Flat Panel Detectors, Line Detectors) and Imaging Plates (Computed Radiography, CR) allow a fast acquisition of radiographic images with higher dynamic than film. Especially DDA’s allow a radiographic inspection with considerable higher image qualit...

Journal: :Journal of the Visualization Society of Japan 2000

2004
J. A. Rowlands

Flat-panel X-ray image detectors have been shown to be suitable to replace the conventional X-ray filmjscreen cassettes for medical radiography (static or snapshot imaging). They are capable of capturing the X-ray image digitally immediately after the X-ray exposure which permits a convenient clinical transition to digital radiography. There are two general approaches to the flat-panel X-ray de...

2004
V. Kaftandjian C. Luc B. Munier

Abstract: In the actual study, two digital detectors were investigated : an amorphous silicon flat panel and a TDI multilinear detector. The contrast and IQI sensitivity was selected to compare flat panel and film radiography. The influence of X-ray conditions was assessed in the case of flat panel. Spatial resolution of both digital detectors was assessed by adapting the geometrical magnificat...

2009
M. A. Yousuf M. Asaduzzaman

Ring artifacts are very troublesome in a flat-panel based micro computed tomography (micro-CT) since they might severely degrade visibility of the micro-CT images. Unlike ring artifacts in other types of micro-CTs such as image-intensifier based micro-CT, ring artifacts in a flat-panel detector based micro-CT are hardly removable since the sensitivity of the pixel elements in a flat-panel detec...

2016

One of these innovations came to life in 2006 with the first introduction of flatpanel detectors (FD) to a mobile C-arm. Ziehm Imaging started the paradigm shift of innovative detector technologies for mobile X-ray imaging from image intensifiers (I. I.) to flat-panel detectors. Other C-arm competitors followed and reconfirmed the trend of implementing amorphous silicon (aSi) flat-panel detecto...

2016
Dongcai Hu Hao Chen Yuan Wang Yunbin Chen Zhou Xu

In the flat panel detector-based cone beam CT system, the scatter photons which reach the flat panel detector increase the detected signal, produce the image cupping artifact and reduce the image contrast. To conquer the X-Ray scatter problem, this study proposes the beam attenuation grid -based scatter correction algorithm that needs to add a beam attenuation grid (BAG) between the X-Ray sourc...

2013
Fabiana Oliveira Paixão Fernandes Cássio Alves Carneiro Petr Ekel Zélia Myriam Assis Peixoto Flávia Magalhães Freitas Ferreira

Several spatial filters applied to images are available in technical and scientific literature. Besides the reduction of the noise level, some of them also aim at the preservation of edges and details. Those filters are commonly applied to the processing of X-ray medical image sequences, which are usually noised due to the low doses of radiation suitable for medical procedures but where the los...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید