نتایج جستجو برای: dose limits
تعداد نتایج: 428973 فیلتر نتایج به سال:
background: the aim of the study was to analyze the effective dose record of occupationally exposed radiation workers at bahawalpur institute of nuclear medicine and oncology department. materials and methods: annual effective doses of occupationally exposed workers were measured by film badge dosimetry by sending the dosimeters to radiation dosimetry laboratory (rdl), pakistan institute of nuc...
Background: Designing and shielding of an appropriate radiography room has been one of the major concerns of radiation scientists since the first decade after the invention of X-rays. Recently, report No.147 of National Council on Radiation Protection and Measurements (NCRP) has been published. In this study the researchers have investigated the effect of new report recommendation on primary an...
background: designing and shielding of an appropriate radiography room has been one of the major concerns of radiation scientists since the first decade after the invention of x-rays. recently, report no.147 of national council on radiation protection and measurements (ncrp) has been published. in this study the researchers have investigated the effect of new report recommendation on primary an...
Y. Lemoigne and A. Caner (eds.), Radiation Protection in Medical Physics, NATO Science for Peace and Security Series B: Physics and Biophysics 1, DOI 10.1007/978-94-007-0247-9_2, © Springer Science+Business Media B.V. 2011 Abstract A number of radiation units exist for representing radiation dose to patients, staff, public and quantities for radiation equipment performance in radiological pract...
the present paper has determined the radioactivity concentrations, which are due to natural occurrence of radionuclides along with heavy metal concentration in water, sediment, and fish from 2 reservoirs in ghana. heavy metal concentrations in all samples were generally within the who safe limits with the average activity concentrations of 238u, 232th, and 40k in water being respectively 0.42±0...
introduction: active personal dosimeters (apds) are well accepted as useful and reliable instruments for individual dosimetry measurements. apds have many advantages compared with passive dosimeters for individual external radiation dose assessments. in routine monitoring, occupational exposure is carried out for verification and demonstration of compliance with the regulatory dose limits. so, ...
Almost 20 years ago, Emami et al. presented a comprehensive set of dose tolerance limits for normal tissue organs to therapeutic radiation, which has proven essential to the field of radiation oncology. The paradigm of stereotactic body radiotherapy (SBRT) has dramatically different dosing schemes but, to date, there has still been no comprehensive set of SBRT normal organ dose tolerance limits...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید