نتایج جستجو برای: column-foundation connection

تعداد نتایج: 260350  

Abdolreza S. Moghadam Masoumeh Farshbaf,

Residual drifts after severe earthquakes interrupt serviceability of buildings. Retrofitting of such buildings is in many cases very difficult and consumes lots of time and money. Recently, there are some attempts to develop the seismic design procedures to not only satisfy life safety criteria but also lead to more economical buildings. One of these modern methods of improving seismic performa...

Results of an experimental investigation of the seismic performance of prefabricated column-footing connections are presented. Tests were conducted on six 1/4-scale prefabricated column specimens inserted into prefabricated footings in two Groups. Group-1 consisted of four specimens, which were tested under constant axial load and cyclic inelastic lateral displacements. The remaining two specim...

Precast concrete structures in Iran are generally designed as continuous columns with hinged beams, thereby making them simple frames. In this system in site show walls in two directions of buildings guaranteed lateral resisting system. However, in order to obtain a seismic resisting frame, the connection between beam and column should be moment resisting and ductile, allowing the formation of ...

Journal: :international journal of civil engineering 0
r. vidjeapriya department of civil engineering, college of engineering guindy, anna university, chennai, sardar patel road, guindy, chennai, india v. vasanthalakshmi department of civil engineering, college of engineering guindy, anna university, chennai, sardar patel road, guindy, chennai, india k. p. jaya department of civil engineering, college of engineering guindy, anna university, chennai, sardar patel road, guindy, chennai, india

the present study focuses on the performance of precast concrete beam-column dowel connections subjected to cyclic loading by conducting experiments. in this study, one-third scale model of two types of precast and a monolithic beam-column connection were cast and tested under reverse cyclic loading. the precast connections considered for this study is a beam-column connection where beam is con...

Journal: :Construction and Building Materials 2022

Four precast column-to-foundation connection specimens, previously tested under lateral reversed cyclic loading and constant axial load (first-stage tests), were repaired with Carbon Fibre Reinforced Polymer (CFRP) layers in the areas where plastic hinges had formed retested same loads (second-stage tests). The columns originally manufactured ultrahigh-performance concrete (UHPC) high stee-fibr...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید