نتایج جستجو برای: X-ray detector

تعداد نتایج: 713717  

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...

جعفرزاده خطیبانی, مرتضی, رحیقی, جواد, کارگر, زهره, کرمی, هاله,

In this paper a one dimentional position-sensitive X-ray gas detector has been designed, simulated and constructed based on Multi Wire Proportional Chamber (MWPC) with delay line position readout. These kinds of detectors are useful in soft X-ray imaging and are capable of being extended to two dimensions position readout easily. The position resolution of this detector is estimated to be 230µm...

Journal: :Medical physics 2011
Hosein Arabi Ali Reza Kamali Asl Mohammad Reza Ay Habib Zaidi

PURPOSE The variable resolution x-ray (VRX) CT scanner provides substantial improvement in the spatial resolution by matching the scanner's field of view (FOV) to the size of the object being imaged. Intercell x-ray cross-talk is one of the most important factors limiting the spatial resolution of the VRX detector. In this work, a new cell arrangement in the VRX detector is suggested to decreas...

Journal: :iranian journal of medical physics 0
ali chaparian medical physic dept., shahid sadoughi university of medical sciences, yazd, iran

introduction individual x-ray diffraction patterns of biological tissues are obtained via interference of coherent scattering with their electrons. many scientists have distinguished normal and cancerous breast tissue, bone density, and urinary stone types using the x-ray diffraction patterns resulting from coherent scattering. the goal of this study was to introduce an optimized method for obt...

Journal: :Medical physics 1999
J M Boone J A Seibert J M Sabol M Tecotzky

Advances in digital x-ray detector systems have led to a renewed interest in the performance of x-ray phosphors and other detector materials. Indirect flat panel x-ray detector and charged coupled device (CCD) systems require a more technologically challenging geometry, whereby the x-ray beam is incident on the front side of the scintillator, and the light produced must diffuse to the back surf...

2002
Wayne H. Baumgartner K. Tamura

The CZT detector on the InFOCμS hard X-ray telescope is a pixellated solid-state device capable of imaging spectroscopy by measuring the position and energy of each incoming photon. The detector sits at the focal point of an 8m focal length multilayered grazing incidence X-ray mirror which has significant effective area between 20–40 keV. The detector has an energy resolution of 4.0 keV at 32 k...

Journal: :IEEE Transactions on Nuclear Science 2001

Journal: :Journal of synchrotron radiation 2009
T Ejdrup H T Lemke K Haldrup T N Nielsen D A Arms D A Walko A Miceli E C Landahl E M Dufresne M M Nielsen

The recent developments in X-ray detectors have opened new possibilities in the area of time-resolved pump/probe X-ray experiments; this article presents the novel use of a PILATUS detector to achieve X-ray pulse duration limited time-resolution at the Advanced Photon Source (APS), USA. The capability of the gated PILATUS detector to selectively detect the signal from a given X-ray pulse in 24 ...

Journal: :IEEE Transactions on Nuclear Science 2002

2004
R. Ghaffarian

The use of x-ray technique now become an additional inspection tool requirement for quality control and unique defect due to manufacturing for implementation of advanced electronic packages such as ball grid array (BGAs) and chip scale packages (CSPs). Recently, four x-ray systems were evaluated for their defect detection capability especially for damagekracks induced during thermal cycling of ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید