نتایج جستجو برای: Wire fixation

تعداد نتایج: 81419  

KEIKHOSROW FIROOZBAKHSH, MOHEB S. MONEIM,

This study compares the functional capabilities of different metacarpal fixation constructs under physiological loadings in an attempt to identify the optimal construct rather than the strongest one. One hundred and twenty-six preserved human metacarpals were mechanically tested after oblique osteotomies and internal fixation. Maximum load to failure, average structural rigidity, and energ...

Journal: :medical journal of islamic republic of iran 0
keikhosrow firoozbakhsh from the department of mechanical engineering, biomechanics division, sharif university of technology, tehran, islamic republic of iran moheb s. moneim the department of orthopedics and rehabilitation, medical school, university of new mexico, albuquerque, new mexico, u.s.a.

this study compares the functional capabilities of different metacarpal fixation constructs under physiological loadings in an attempt to identify the optimal construct rather than the strongest one. one hundred and twenty-six preserved human metacarpals were mechanically tested after oblique osteotomies and internal fixation. maximum load to failure, average structural rigidity, and energy abs...

2017
Seung Woo Lee Dong Chul Lee Jin Soo Kim Si Young Roh Kyung Jin Lee

BACKGROUND Adequate fixation of replanted digits is essential not only for short-term healing but for long-term function. Various bony fixation methods using Kirschner (K-) and intraosseous wire are available in replantation. We examined clinical and radiographic outcomes of fixation methods on bone union after digital replantation. METHODS A single institutional retrospective review identifi...

Journal: :International journal of clinical and experimental medicine 2014
Yi-Hua Ge Zhi-Gang Wang Hai-Qing Cai Jie Yang Yun-Lan Xu Yu-Chan Li

The effectiveness evaluation of flexible intramedullary nailing (FIN) and kirschner wire fixation (K-wire) used for MDJ fractures fixation have been described in multiple reports. But there have been few reports about comparison between FIN and K-wire in children with distal humeral MDJ fracture. In our retrospective study, Nineteen children received K-wire and twenty children received FIN, dur...

2016
Haoqi Cai Zhigang Wang Haiqing Cai

OBJECTIVE To compare the use of crossed K-wire and prebent intramedullary nail techniques for the fixation of distal radius metaphyseal fracture in children. METHODS Intraoperative and follow-up data for children with distal radius metaphyseal fracture, treated using crossed K-wire or prebent intramedullary nail fixation, were retrospectively analysed. Patient groups were matched for age, sex...

Journal: :Orthopedics 2013
Hyoung Keun Oh Suk Kyu Choo Chang Soo Lee Jae Gwang Song

Olecranon fractures are intra-articular injuries that require anatomic restoration of the articular surface. For most simple noncomminuted transverse olecranon fractures, tension band wire fixation can provide a stable construct to allow for early joint range of motion. However, in comminuted olecranon fractures, it is difficult to provide a sufficient buttress for impacted articular fragments ...

Journal: :Veterinary journal 2016
Scott A Christopher Stanley E Kim Simon Roe Antonio Pozzi

Periprosthetic femoral fractures are a common complication associated with cementless press-fit total hip arthroplasty. The use of prophylactic cerclage wire fixation has been advocated to reduce this complication. The objective of this study was to evaluate whether a double loop cerclage wire, used as adjunctive fixation, increased the peak torsional load to failure in femora implanted with pr...

Journal: :Journal of orthopaedic surgery 2012
Michael G Jakubietz Robert Zahn Joerg G Gruenert Jens Waschke Rainer H Meffert Rafael G Jakubietz

PURPOSE To compare 5 different Kirschner wire fixation techniques in terms of the failure loads seen as scapholunate (SL) dissociation in a cadaveric, biomechanical study. METHODS 10 fresh-frozen, finger-amputated wrists with sectioned SL ligaments from 3 male and 2 female cadavers were tested. The change of SL angle, SL dissociation, and the load to failure of the 5 different Kirschner wire ...

Journal: :Orthopedics 2011
T Ty Fowler Kevin J Pugh Alan S Litsky Benjamin C Taylor Bruce G French

Fracture fixation of the medial malleolus in rotationally unstable ankle fractures typically results in healing with current fixation methods. However, when failure occurs, pullout of the screws from tension, compression, and rotational forces is predictable. We sought to biomechanically test a relatively new technique of bicortical screw fixation for medial malleoli fractures. Also, the AO gro...

2018
D. Franks J. Shatrov M. Symes D. G. Little T. L. Cheng

Purpose Lateral condyle fractures of the humerus are common in the paediatric population, accounting for up to 20% of elbow fractures. Traditional management involves internal fixation with Kirschner (K)-wires, however, this has been associated with complications and insufficiently rigid fixation. Recently, cannulated screws have been proposed as a more stable method of fixation. While cannulat...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید