run-out-table (rot) is located between last finishing stand and down coiler in a hot strip mill. as the hot steel strip passes from rot, water jets impact on it from top and bottom and strip temperature decreases approximately from 800-950 °c to 500-750°c. the temperature history that strip experience while passing through rot affects significantly the metallurgical and mechanical properties, s...
conclusions unless there are well-thought out strategies for minimizing the undesirable impact on the environment, it is not advisable that such projects be permitted. results the results showed that the negative environmental and social impacts of the project outweighed the positive impacts in terms of type, number, and intensity. materials and methods a checklist containing the positive, nega...
this study aimed to find an appropriate way to minimize water utility in the petrochemical and petroleum industries. for this purpose, tehran oil refinery was chosen to analyze feasibilities of regeneration, reuse and recycling in the water network. in this research, two key contaminants including cod and hardness were analyzed. amount of freshwater was reduced about 180 m3/h (53%) and 216.88 m...
0
چکیده ندارد.
in this work, the characteristics of flow and heat transfer of a fluid containing nano particles of aluminum oxide with the water volume fraction (0.1-0.2-0.3)(v/v) percent of the reports. the overall heat transfer coefficient, heat transfer and the average heat transfer fluid containing nano water - aluminum oxide in a horizontal double pipe counter flow heat exchanger under turbulent flow con...
In this paper, overall heat transfer coefficient and friction factor of water based γ-Al2O3 nanofluid in a double tube counter flow heat exchanger have been measured experimentally under turbulent flow condition. For better dispersion of γ-Al2O3 nanoparticles in distilled water, magnetic stirrer and ultrasonic vibrator (with a power of 240 kW and frequency of 35 kHz) were implemented. The stabi...
the abrasion is a significant issue, especially in machining of rigid steels. a functional and suitable approach for enhancing the heat transfer from machining area is using an intermediate fluid with higher heat transfer potential instead of common fluids. the objective of this experimental study is to discuss production, stability and thermal conductivity examination of water/graphene oxide n...
some new water-soluble schiff base complexes of na2[m(5-so3-1,2-salophen)].nh2o; (5-so3-1,2-salophen = n,n’-bis(5-sulphosalicyliden)-1,2-phenylendiamine); na2[m(5-so3-2,3-salpyr)(h2o)n].2h2o; (5-so3-2,3-salpyr = n,n’-bis(5-sulphosalicyliden)-2,3-diaminopyridine); and na2[m(5-so3-3,4-salbenz)(h2o)n].nh2o; (5-so3-3,4-salbenz = n,n’-bis(5-sulphosalicyliden)-3,4-diaminobenzophenon); where m = cu, n...
The abrasion is a significant issue, especially in machining of rigid steels. A functional and suitable approach for enhancing the heat transfer from machining area is using an intermediate fluid with higher heat transfer potential instead of common fluids. The objective of this experimental study is to discuss production, stability and thermal conductivity examination of water/graphene oxide n...