نتایج جستجو برای: Volumetric-Modulated Arc Therapy

تعداد نتایج: 761818  

2016
Guanming Lao Zhaohui Zhang Meilan Luo Daomu Zhao

We introduce a method for modulating the Gaussian beam by means of sine-azimuthal wavefront and carry out the experimental generation. The analytical propagation formula of such a beam passing through a paraxial ABCD optical system is derived, by which the intensity properties of the sine-azimuthal wavefront modulated Gaussian (SWMG) beam are examined both theoretically and experimentally. Both...

2017
Tomomi Suwa Satoshi Tomita Nobuyoshi Hosoito Hisao Yanagi

Herein we experimentally study magnetic multilayer metamaterials with broken translational symmetry. Epitaxially-grown iron-gold (Fe-Au) multilayers modulated using Fibonacci sequence-referred to as magnetic inverse Fibonacci-modulated multilayers (IFMs)-are prepared using ultra-high-vacuum vapor deposition. Experimental results of in-situ reflection high-energy electron diffraction, magnetizat...

Journal: :Nature materials 2005
Manish Chhowalla H Emrah Unalan

Hard, refractory thin films consisting of group IVB element mono-nitrides deposited using various chemical and physical vapour-deposition techniques are widely used in wear-resistant applications. As the demand for performance exceeds the capabilities of existing materials, new materials with superior properties must be developed. Here we report the realization and characterization of hard cubi...

Journal: :Medical physics 2015
Jan Unkelbach Thomas Bortfeld David Craft Markus Alber Mark Bangert Rasmus Bokrantz Danny Chen Ruijiang Li Lei Xing Chunhua Men Simeon Nill Dávid Papp Edwin Romeijn Ehsan Salari

Volumetric modulated arc therapy (VMAT) has found widespread clinical application in recent years. A large number of treatment planning studies have evaluated the potential for VMAT for different disease sites based on the currently available commercial implementations of VMAT planning. In contrast, literature on the underlying mathematical optimization methods used in treatment planning is sca...

Journal: :Physics in medicine and biology 2010
Thomas Bortfeld

The first purpose of this paper is to shed some new light on the old question of selecting the number of beams in intensity-modulated radiation therapy (IMRT). The second purpose is to illuminate the related issue of discrete static beam angles versus rotational techniques, which has recently re-surfaced due to the advancement of volumetric modulated arc therapy (VMAT). A specific objective is ...

Journal: :Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 2011
Barbara Dobler Christian Groeger Marius Treutwein Judith Alvarez-Moret Thomas Goetzfried Karin Weidner Petra Haertl Oliver Koelbl

Methods and results for commissioning of the complete VMAT delivery chain are presented for the combination of Nucletron's Oncentra MasterPlan® v3.3 with Elekta's Mosaiq® v1.6 and SynergyS® linac. VMAT specific linac commissioning included determination of the size of the minimal dynamic leaf gap. Dosimetric validation of the complete treatment chain was performed using a 2D-ionization-chamber-...

2012
C. W. Ebeling E. A. Okal N. Kalligeris

Article history: Received 26 May 2011 Received in revised form 20 December 2011 Accepted 23 December 2011 Available online 2 January 2012

2017
Jung-in Kim Minsoo Chun Hong-Gyun Wu Eui Kyu Chie Hak Jae Kim Jin Ho Kim Jong Min Park

To report a single-institution experience of gamma evaluations with 2%/1 mm for stereotactic ablative radiotherapy (SABR) delivered with volumetric modulated arc therapy (VMAT) technique, from January 2014 to January 2016. A total of 168 SABR VMAT plans were analyzed with a gamma criterion of 2%/1 mm, a threshold value of 10%, and a tolerance level of 90%. Of the 168 cases, four cases failed wi...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید