Introduction: Wedge filters are commonly used in radiation oncology for eliminating hot spots and creating a uniform dose distribution in optimizing isodose curves in the target volume for clinical aspects. These are some limited standard physical wedges (15°, 30°, 45°, 60°), or creating an arbitrary wedge angle, like motorized wedge or dynamic wedge, ... The new formulation is...
BACKGROUND Wedge filters are commonly used in radiation oncology for eliminating hot spots and creating a uniform dose distribution in optimizing isodose curves in the target volume for clinical aspects. These are some limited standard physical wedges (15°, 30°, 45°, 60°),or creating an arbitrary wedge angle, like motorized wedge or dynamic wedge,... The new formulation is presented by the comb...
background: physical wedges are still widely used as beam modifiers in external beam radiotherapy. however the presence of them in the beam trace may cause beam hardening which may not be considered in many treatment planning systems. the aim of this study is to investigate the beam hardening effect generated by physical wedges via different beam quality indexes as photon spectrum, half value l...
background: in radiation therapy, the peripheral dose is important when anatomical structures with very low dose tolerances are involved. in this study, the two available calculation algorithms of the varian eclipse 8.6 treatment planning system(tps), the anisotropic analytic algorithm (aaa) and pencil-beam convolution (pbc) was used to compare measured and calculated peripheral dose distributi...
background: the presence of a wedge filter in the beam trajectory can modify the beam quality and cause some changes in the dosimetry parameters which are usually difficult to be measured directly and accurately. material and methods: in this study the mcnp-4c monte carlo code was used to simulate the 9 mv photon beam generated by a linear accelerator. upon getting a good agreement between the ...
This research aimed to measure the received photon and thermal neutron doses to contralateral breast (CB) surface in breast cancer radiation therapy for different field sizes in presence of dynamic and physical wedges. The photon and thermal neutron doses were measured by thermo uminescent dosimeter (TLDs) chips for 11 × 13, 11 × 17 and 11 × 21 cm2 field sizes in presence of physical and dynamic ...
Introduction: Wedge filters are used in radiotherapy to modify photon beam and improve dose uniformity in the target volume. Determination of wedge dose distribution is important to improve treatment planning accuracy. The utilization of treatment planning software to obtain dose distribution is not always available. In this work an analytical model has been developed to calcu...
A non-physical wedge generates a spatial dose distribution similar to that produced by a physical wedge without a physical filter in the photon beam. Instead, an exponential fluence profile is produced via motion of one of the collimating jaws. Proposed in the late 1970s, nonphysical wedges have been implemented on both Varian and Siemens’ accelerators as the Varian Dynamic Wedge (DW) and Sieme...
BACKGROUND Wedge filters can be used as missing tissue compensators or wedge pairs to alter the shape of isodose curves so that two beams can be angled with a small hinge angle at a target volume without creating a hotspot. AIM In this study the dosimetric properties of Varian Enhanced Dynamic Wedge (EDW) and physical wedges (PW) were analyzed and compared. MATERIALS AND METHODS Ionometric ...