نتایج جستجو برای: Treatment planning system
تعداد نتایج: 3598653 فیلتر نتایج به سال:
background: most of the current brachytherapy treatment planning systems (tps) use the tg-43u1 recommendations for dosimetry in water phantom, not considering the heterogeneity effects. objective: the purpose of this study is developing a method for obtaining correction factors for heterogeneity for cs-137 brachytherapy sources based on pre-calculated mc simulations and interpolation. method: t...
background: accelerated partial breast irradiation via interstitial balloon brachytherapy is a fast and effective treatment method for certain early stage breast cancers however skin, chest wall and lung doses are correlated with toxicity in patients treated with breast brachytherapy. objective: to investigate the percentage of the dose received by critical organ (skin), thermoluminescence dete...
background: it was intended to investigate the effect of physical wedge (pw) and enhanced dynamic wedges (edw) on contralateral breast dose during primary breast irradiation in radiotherapy treatment, using high energy photon beams. materials and methods: the varian’s clinac dual mode linear accelerator model 2100 c/d and siemen’s primus accelerators were used for radiation doses with 6 mv and ...
Introduction: In radiation therapy, in order to double-check the dosimetric results of the main treatment planning system (TPS), a distinct TPS, with few capacitances in terms of contouring and a variety of dose calculation algorithms is used. This system has the capability to double check the planification and the accurate prediction of dose distribution in order to be ensured...
Background: Most of the current brachytherapy treatment planning systems (TPS) use the TG-43U1 recommendations for dosimetry in water phantom, not considering the heterogeneity effects.Objective: The purpose of this study is developing a method for obtaining correction factors for heterogeneity for Cs-137 brachytherapy sources based on pre-calculated MC simulations and interpolation.Method: To ...
an important need in radiation therapy is a fast and accurate treatment planning system. this system using ct data and characteristics of the radiation beam, calculates the dose in all points of the patient’s volume. two main factors in planning system are “accuracy” and “speed”. according to these factors, various generation of treatment planning systems are developed. this article is the re...
background: the dosimetric performance of eclipse 6.5 three dimensional treatment planning system (3dtps) is evaluated by comparing the calculated and measured dose in two dimensions following the guide lines of american association for physicists in medicine task group 53. materials and methods: the calculations were performed by the 3dtps for symmetric as well as asymmetric fields for standar...
introduction: this study investigates to what extent the computed dose received by lung tissue in a commercially available treatment planning system (tps) for 192ir high-dose-rate breast brachytherapy is accurate in view of tissue inhomogeneities and presence of ribs. materials and methods: a ct scan of the breast was used to construct a patient-equivalent phantom in the clinical treatment plan...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید