نتایج جستجو برای: Treatment Couch

تعداد نتایج: 1395060  

Ali Asghar Mowlavi, Azam Afzalifar Mohammad Mohammadi, Sara Abdollahi

Introduction: The accuracy of patient positioning plays an important role for radiotherapy tasks. Short and automated Quality Assurance (QA) programs are becoming one of the challenging tasks in Radiotherapy. The current study, investigates the accuracy of treatment couch positioning with four degrees of freedom (4DoF) using a fast and accurate method based on an image acquired...

J. Fleckenstein, M.C. Miao, R.H. Zhang, W.W. Bai, Y.L. Gao, Z.F. Chi,

Background: As the volumetric modulated arc therapy (VMAT) becoming a main role of treatment ways, the effect of couch top becomes more significant. It is imperative to re-evaluate the couches that previously may have been considered of no importance during early treatment techniques. The impact of couch top on radiation delivery was explored and the couch model was tested with the aim of reduc...

2011
Zhihui Hu Jianrong Dai Liang Li Yin Cao Yixin Song Guishan Fu

The purpose of this study was to evaluate beam attenuation by treatment couch and build a treatment couch model in TPS to check for beam-couch intersection at the planning stage and deal with beam attenuation by treatment couch in dose calculation. In this study, a standard treatment couch, Siemens ZXT couch, has been incorporated into Pinnacle3 8.0 TPS, based on an existing TPS tool, model-bas...

2018
Ruohui Zhang Yulan Gao Wenwen Bai

The use of Monte Carlo treatment planning systems (TPS) in radiation therapy has increased the dosimetric accuracy of VMAT treatment sequences. However, this accuracy is compromised by not including the treatment couch into the treatment planning process. Therefore, the impact of the treatment couch on radiation delivery output was determined, and two different couch models (uniform couch model...

Journal: :Medical physics 2012
R Ter-Antonyan D Frieda

PURPOSE We investigate the impact of a treatment couch and its modeling in a treatment planning system on accurate dose delivery in Volumetric Modulated Arc Therapy (VMAT). METHODS A cone-beam CT of a Varian couch on a Varian Clinac 21EX unit, consisting of a carbon-fiber imaging couch top and supporting rails, was acquired, and a couch model was created in Philips Pinnacle 9.0 TPS based on t...

2005
Patrick Towns Blair Free George Cernica Matthew B. Podgorsak

Safe delivery of external beam radiation therapy to patients whose weight approaches the tolerance of a treatment couch presents some challenges, particularly if the couch has been in use for several years and has seen significant wear and tear. An analysis of treatment couch design can identify locations that become stressed and could potentially fail when supporting a heavy patient, leading t...

2006
W. Kenji Myint Malgorzata Niedbala David Wilkins Lee H. Gerig

Carbon fiber is commonly used in radiation therapy for treatment tabletops and various immobilization and support devices, partially because it is generally perceived to be almost radiotransparent to high-energy photons. To avoid exposure to normal tissue during modern radiation therapy, one must deliver the radiation from all gantry angles; hence, beams often transit the couch proximal to the ...

2010
Monique van Prooijen Thilakshan Kanesalingam Mohammad K. Islam Robert K. Heaton

The impact of the treatment couch on a radiotherapy plan is rarely fully assessed during the treatment planning process. Incorporating a couch model into the treatment planning system (TPS) enables the planner to avoid or dosimetrically evaluate beam-couch intersections. In this work, we demonstrate how existing TPS tools can be used to establish this capability and assess the accuracy and effe...

Journal: :Physics in medicine and biology 2011
Kiley B Pulliam Rebecca M Howell David Followill Dershan Luo R Allen White Stephen F Kry

The clinical impact of the Varian Exact Couch on dose, volume coverage to targets and critical structures, and tumor control probability (TCP) has not been described. Thus, we examined their effects on IMRT and arc therapy. Five clinical prostate patients were planned with both 6 MV eight-field IMRT and 6 MV two-arc RapidArc techniques using the Eclipse treatment planning system. These plans ne...

2002
Milton K. Woo Bryan Kim

Radiation therapy techniques that incorporate multiple couch motions are becoming more common, and they often involve an increasing level of complexity along with a need for automatic motion. The reproducibility of automatic couch motion is thus a growing concern. In this work we carried out various tests to assess the automatic motion of a commercial treatment couch, including tests to evaluat...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید