نتایج جستجو برای: Tail cuff

تعداد نتایج: 62106  

Journal: :iranian journal of basic medical sciences 0
mohsen imenshahidi pharmaceutical research center, department of pharmacodynamy and toxicology, school of pharmacy, mashhad university of medical sciences, mashhad, iran bibi marjan razavi targeted drug delivery research center, department of pharmacodynamy and toxicology, school of pharmacy, mashhad university of medical sciences, mashhad, iran ayyoob faal school of pharmacy, mashhad university of medical sciences, mashhad, iran ali gholampoor school of pharmacy, mashhad university of medical sciences, mashhad, iran seyed mehran mousavi school of pharmacy, mashhad university of medical sciences, mashhad, iran hossein hosseinzadeh pharmaceutical research center, department of pharmacodynamy and toxicology, school of pharmacy, mashhad university of medical sciences, mashhad, iran

objective(s): in this study, the effects of chronic administration of crocin, an active constituent of saffron, on blood pressures of normotensive and desoxycorticosterone acetate (doca) - salt induced hypertensive rats, were investigated.   materials and methods: five week administration of three doses of crocin (50, 100 and 200 mg/kg/day) and spironolactone (50 mg/kg/day) in different groups ...

Journal: :American journal of hypertension 2008
Minjie Feng Steven Whitesall Yunyu Zhang Martin Beibel Louis D'Alecy Keith DiPetrillo

BACKGROUND The American Heart Association has recommended tail-cuff blood pressure measurement for high-throughput experimental designs, including mutagenesis screens and genetic crosses. However, some tail-cuff methods show good agreement with radiotelemetry and others do not, indicating that each tail-cuff method requires independent validation. METHODS We validated the volume-pressure reco...

Journal: :iranian journal of pharmaceutical research 0
mohsen imenshahidi pharmaceutical research center, department of pharmacodynamy and toxicology, school of pharmacy, mashhad university of medical sciences marjan razavi school of pharmacy, mashhad university of medical sciences, ayyoob faal school of pharmacy, mashhad university of medical sciences, mashhad ali gholampoor school of pharmacy, mashhad university of medical sciences seyedmehran mousavi school of pharmacy, mashhad university of medical sciences hossein hosseinzadeh mashhad

safranal, the main component of crocus sativus essential oil, exhibits different pharmacological activities. in this study, the effects of safranal, on blood pressure of normotensive and desoxycorticosterone acetate (doca) - salt induced hypertensive rats in chronic administration were investigated. three doses of safranal (1, 2 and 4 mg/kg/day) and spironolactone (50 mg/kg/day) were administra...

2017
Elena Wilde Aisah A. Aubdool Pratish Thakore Lineu Baldissera Khadija M. Alawi Julie Keeble Manasi Nandi Susan D. Brain

BACKGROUND Reliable measurement of blood pressure in conscious mice is essential in cardiovascular research. Telemetry, the "gold-standard" technique, is invasive and expensive and therefore tail-cuff, a noninvasive alternative, is widely used. However, tail-cuff requires handling and restraint during measurement, which may cause stress affecting blood pressure and undermining reliability of th...

Journal: :American journal of physiology. Heart and circulatory physiology 2004
Steven E Whitesall Janet B Hoff Alan P Vollmer Louis G D'Alecy

Radiotelemetry of mouse blood pressure accurately monitors systolic pressure, diastolic pressure, heart rate, and locomotor activity but requires surgical implantation. Noninvasive measurements of indirect systolic blood pressure have long been available for larger rodents and now are being reported more frequently for mice. This study compared mouse systolic arterial blood pressure measurement...

Journal: :Clinical science 1997
R E Widdop X C Li

1. The non-invasive measurement of tail cuff systolic blood pressure in conscious rats is routinely used in long-term cardiovascular studies. There are a number of commercially available tail cuff systems, however, these apparatus are generally expensive and are dedicated for single-task operations. In the present study, a simple method for measuring systolic blood pressure, which requires only...

Journal: :Journal of applied physiology 1973
R D Buñag

Bu~~AG, RUBEN D. Validation in awake rats of a tail-cuf method for measuring systolic pressure. J. Appl. Physiol. 34(2) : 279-282. 1973. -To determine why results of recent studies on applicability of the tail-cuff method to awake rats have been conflicting, arterial pressures were measured under various conditions. A Doppler ultrasonic flowmeter was used to detect blood flow changes occurring ...

Journal: :Hypertension 1987
R L Kline P F Mercer

Angiotensin I converting enzyme inhibitors are typically classified as peripheral vasodilators. We studied the effect of captopril and a known vasodilator, hydralazine, on arterial pressure-urinary output relationships in adult spontaneously hypertensive rats to determine whether these drugs produced similar changes in this relationship. Tail-cuff pressure and 24-hour urine output and sodium ex...

2015
Christopher M. Haggerty Andrea C. Mattingly Ming C. Gong Wen Su Alan Daugherty Brandon K. Fornwalt German E. Gonzalez

Abdominal aortic aneurysm (AAA) is a disease of the aortic wall, which can progress to catastrophic rupture. Assessment of mechanical characteristics of AAA, such as aortic distensibility, may provide important insights to help identify at-risk patients and understand disease progression. While the majority of studies on this topic have focused on retrospective patient data, recent studies have...

2009
Alan Daugherty Debra Rateri Lu Hong Anju Balakrishnan

The CODA 8-Channel High Throughput Non-Invasive Blood Pressure system measures the blood pressure in up to 8 mice or rats simultaneously. The CODA tail-cuff system uses Volume Pressure Recording (VPR) to measure the blood pressure by determining the tail blood volume. A specially designed differential pressure transducer and an occlusion tail-cuff measure the total blood volume in the tail with...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید