نتایج جستجو برای: TRS 398

تعداد نتایج: 5492  

2009
E. M. Attalla A. A. Elsayed N. E. Khaled H. S. Abou-elenein

Introduction: In the last 5 years the American Association of Physicists in Medicine Task Group 51 (AAPM TG-51) and the International Atomic Energy Agency (IAEA) published a new high-energy photon and electron dosimetry protocol. These protocols are based on the use of an ion chamber having an absorbed-dose to water calibration factor. These are different from the previous NCS report-2 and IAEA...

A. Mostaar, H. Alijanzadeh, M. Mahdavi, M. Zabihzadeh, S.R.M. Mahdavi,

Background: Two protocols of AAPM TG-51 and IAEA TRS-398 were compared followed by a measurement and Monte Carlo simulation of beam quality correction factor, KQ, AAPM TG-51 and IAEA TRS-398 protocols were compared for the absorbed dose to water for DW, and KQ parameters. Materials and Methods: Dose measurements by either protocols were performed with cylindrical and plane parallel ch...

Journal: :Iraqi journal of science 2022

Modern radiotherapy facilities like 3-Dimensional conformal radio therapy (3DCRT), Intensity Modulated Radiotherapy (IMRT), were recently suggested in Co-60 machine with Multi-leaf Collimator (MLC). In this study, two reference chambers NE-2571#1205 and NE2581#537 used for absolute dose measurement Equinox accelerator. A comparison of by different IAEA protocols TRS-277 TRS-398 has been studied...

Journal: :iranian journal of radiation research 0
s.r.m. mahdavi department of medical physics, tehran university of medical sciences, tehran, iran m. mahdavi department of physics, faculty of basic sciences, mazandaran university, babolsar, iran h. alijanzadeh department of physics, faculty of basic sciences, mazandaran university, babolsar, iran m. zabihzadeh department of medical physics, joundishapour university of medical sciences, ahvaz, iran a. mostaar department of medical physics, faculty of medicine, shahid beheshti university of medical sciences, tehran, iran

background: two protocols of aapm tg-51 and iaea trs-398 were compared followed by a measurement and monte carlo simulation of beam quality correction factor, kq, aapm tg-51 and iaea trs-398 protocols were compared for the absorbed dose to water for dw, and kq parameters. materials and methods: dose measurements by either protocols were performed with cylindrical and plane parallel chambers for...

Journal: :Brazilian Journal of Radiation Sciences 2023

The Technical Report Series 398 (TRS-398), Electron Dosimetry Working Party (EWDP), and Task Group 51 (TG 51) are the most important protocols for reference dosimetry. In case of electron beam dosimetry, these recommend using parallel-plate ionization chambers beams with R50 values below specific thresholds. However, recent papers suggested cylindrical dosimetry all energies. Here we compared d...

2004
Božidar Casar Urban Zdešar Vlado Robar

Introduction. In the International Code of Practice for dosimetry TRS-398 published by International Atomic Energy Agency (IAEA), water is recommended as the reference medium for the determination of absorbed dose for high-energy electron beams. Plastic phantoms may be used under certain circumstances for electron beam dosimetry for beam qualities R50 < 4g/cm2 (E0 below 10 MeV). In our study, w...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه مازندران - دانشکده علوم پایه 1388

در این پایان نامه، فاکتور تصحیح کیفیت، ، توسط کد mcnp به روش مونت کارلو برای قوی تر کردن دزیمتری کلینیکی شبیه سازی شد و پروتوکل های aapm tg-51 وiaea trs-398 برای پارامتر های و دز جذبی آب، ، مورد مقایسه قرار گرفته اند. اندازه گیری های دز در هر دو پروتوکل توسط چمبر های صفحه موازی و استوانه ای برای پرتو های فوتون کلینیکی mv 18 و 6 و الکترون های mev 18 و 15، 12، 9، 6 قابل ردیابی به فاکتور کالیبر...

2006
D. MIHAILESCU M. PIMPINELLA A. S. GUERRA R. F. LAITANO D. Mihailescu

Stopping power ratios sw,air for electron beams produced by the NOVAC7® IORT accelerator were calculated at different depths in water by the SPRRZnrc Monte Carlo code. As input for the SPRRZnrc code a phase-space data file obtained for any beam by the BEAMnrc code was used. The calculated stopping power ratios were compared with those recommended by the IAEA dosimetry protocols TRS-381 and TRS-...

2008
Elizabeth A Vianello Luiz Tauhata

A pilot study was performed to verify the troubles involved in the implementation of dosimetric protocol TRS 398 for absorbed-dose-to-water, using clinical high-energy electron beams and to accomplish an detailed evaluation of uncertainty chain components associated to the measurement, which ones were not treated in the IAEA protocols, aimed the standardization of technical procedures.

Journal: :Physics in medicine and biology 2016
Hugo Palmans Stanislav M Vatnitsky

We comment on a recent article (Gomà et al 2014 Phys. Med. Biol. 59 4961-71) which compares different routes of reference dosimetry for the energy dependent beam monitor calibration in scanned proton beams. In this article, a 3% discrepancy is reported between a Faraday cup and a plane-parallel ionization chamber in the experimental determination of the number of protons per monitor unit. It is...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید