نتایج جستجو برای: TLD-100

تعداد نتایج: 415993  

2007
Stephen F. Kry Michael Price David Followill Firas Mourtada Mohammad Salehpour

The commonly used thermoluminescent dosimeter TLD-100 (Harshaw Chemical Company, Solon, OH) responds not only to photons and electrons, but also to neutrons that are produced during high-energy therapies. As a result, TLD-100 measurements outside of the treatment field are suspect when high-energy radiation is used. Although alternatives such as TLD-700 do not respond to neutrons, specialty dos...

Journal: :Cumhuriyet Science Journal 2023

Thermal quenching is described as a decrease in luminescence efficiency with increasing measurement temperature. Luminescence intensity decreases heating rates the presence of thermal quenching. In such case, rate to be used measurements becomes important. Lithium fluoride (LiF) type dosimeters have been widely radiation dosimetry for many years. this study, effect was investigated LiF:Mg,Ti (T...

2007
Ana F. Maia Linda V.E. Caldas

Tandem systems formed with different thermoluminescent dosemeters were evaluated in standard diagnostic radiation beams. The utilized materials are commercially available, and the aim of this study was to carry out a performance comparison. The results show that the energy dependence of the materials, except TLD-100, were very high. Therefore, there are several possibilities of pair combination...

Journal: :Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics 2008
B Hill A J Venning C Baldock

Polymer gel dosimetry undertaken on a multislice CT scanner provides an alternative method to conventional dosimetry measurements. Polymer gel dosimeters were used to measure CT radiation doses and compared to TLD and ionization chamber measurements in different diameter phantoms. CTDI was investigated for each of these phantoms for a range of mAs (100-400 mAs), tube voltage (100-135 kV) and no...

2014
SM Hosseini Pooya T Orouji

BACKGROUND The accurate results of the individual doses in personal dosimety which are reported by the service providers in personal dosimetry are very important. There are national / international criteria for acceptable dosimetry system performance. Objective : In this research, the sources of uncertainties are identified, measured and calculated in a personal dosimetry system by TLD. METHO...

2008
Maria Inês Teixeira Sonia G. P. Cecatti Linda V. E. Caldas

Cases involving high-doses of ionizing radiation are becoming increasingly common.The objective of this work was to characterize thermoluminescent materials for the dosimetry of workers exposed to high doses. Samples of TLD-200, TLD-400 and TLD-800 pellets from Thermo Electron Corporation were studied in gamma high-doses. Dose-response curves were obtained for doses between 100 mGy and 100 Gy. ...

2003
Francisco Aguirre Ramesh C. Tailor Geoffrey S. Ibbott Marilyn Stovall William F. Hanson

The University of Texas M.D. Anderson Cancer Center (UTMDACC) has extensive experience with thermoluminescent dosimetry (TLD) as a quality assurance tool for output and energy monitoring of radiation therapy beams. Over the past 25 years the TLD results of the monitored institutions, commissioning data for TLD readers, the characterization data of lithium fluoride TLD-100 powder and the records...

Journal: :Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi 2021

Tanısal radyolojide görüntü kalitesi önemli bir rol oynamaktadır. Dijital görüntülemenin, görüntüleri sayısal olarak elde etme, işleme ve saklama gibi avantajları vardır. dedektörlerin geniş dinamik aralığa sahip olması, daha iyi kalitede görüntülerin edilmesine olanak sağlar. Ancak hasta dozunda artışa sebep olabilmektedir. Bu nedenle optimizasyonunun, doz ölçümleri ile beraber yürütülmesi ger...

Journal: :Medical physics 2012
M Lawless S Junell C Hammer L DeWerd

PURPOSE Thermoluminescent dosimeters are used routinely for dosimetric measurements of photon and electron fields. However, no work has been published characterizing TLDs for use in combined photon and electron fields. This work investigates the response of TLD-100 (LiF:Mg,Ti) in mixed fields of photon and electron beam qualities. METHODS TLDs were irradiated in a 6 MV photon beam, 6 MeV elec...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید