نتایج جستجو برای: TLD Reader

تعداد نتایج: 29785  

Journal: :journal of biomedical physics and engineering 0
sm hosseini pooya iran nuclear regulatory authority, tehran, iran t orouji iran nuclear regulatory authority, tehran, iran

background: the accurate results of the individual doses in personal dosimety which are reported by the service providers in personal dosimetry are very important. there are national / international criteria for acceptable dosimetry system performance. objective: in this research, the sources of uncertainties are identified, measured and calculated in a personal dosimetry system by tld. method:...

2000
M. S. Kulkarni Ratna Pradeep

Personnel monitoring of more than 40,000 radiation workers in India is being carried out routinely using a Bhabha Atomic Research Centre (BARC) made thermoluminescent dosimeter (TLD) badge based on CaSO4:Dy phosphor embedded in Teflon discs [1], and a photographic film badge. Till recently the TLD badges were read using the manual type TLD badge reader system with an external interface unit for...

2001
Guenther Reitz Gautam Badhwar

Preliminary TLD results from the DOSMAP experiment on ISS G. Reitz, S. Deme, I. Apathy 1 German Aerospace Center (DLR), Cologne, Germany 2 KFKI Atomic Energy Research Institute, Budapest, Hungary Abstract: The Dosimetric Mapping (DOSMAP) experiment, operated by Expedition Two onboard the ISS attempted to record and map radiation inside Space Station within a four month period. One of the severa...

2014
SM Hosseini Pooya T Orouji

BACKGROUND The accurate results of the individual doses in personal dosimety which are reported by the service providers in personal dosimetry are very important. There are national / international criteria for acceptable dosimetry system performance. Objective : In this research, the sources of uncertainties are identified, measured and calculated in a personal dosimetry system by TLD. METHO...

Journal: :Medical physics 1992
T H Kirby W F Hanson D A Johnston

Thermoluminescence dosimeters (TLD) are widely used to verify absorbed doses delivered from radiation therapy beams. Specifically, they are used by the Radiological Physics Center for mailed dosimetry for verification of therapy machine output. The effects of the random experimental uncertainties of various factors on dose calculations from TLD signals are examined, including: fading, dose resp...

2000
U. German B. Ben-Shachar M. Weinstein

In the early years, the routine personal dosimetry at the Nuclear Research CenterNegev was performed by using photographic films. In 1975, the TLD method was introduced. The routine personal dosimetry was performed by using the LiF:Mg, Ti phosphors (G-1 cards), and employing an automatic Harshaw 2271 reader. The heating of the phosphor was performed by a hot finger, and the integral light outpu...

SM Hosseini Pooya, T Orouji

Background: The accurate results of the individual doses in personal dosimety which are reported by the service providers in personal dosimetry are very important. There are national / international criteria for acceptable dosimetry system performance.Objective: In this research, the sources of uncertainties are identified, measured and calculated in a personal dosimetry system by TLD.Method: T...

1999
Ramesh C. Tailor J. Francisco Aguirre William F. Hanson

The Radiological Physics Center (RPC) has been utilizing TLD to verify photon-beam output, and electron-beam output and energy for many years. The RPC currently monitors over 1200 institutions, monitoring 4000 photon and 3500 electron beams per year. Control TLD, irradiated on one specific Co-60 machine, are used for a performance check of our TLD system. Analysis of these data over 5 years, re...

Journal: :Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 2003
Daniela Kroutilķková Josef Novotný Libor Judas

INTRODUCTION The Czech thermoluminescent dosimeters (TLD) quality assurance network was established in 1997. Its aim is to pursue a regular independent quality audit in Czech radiotherapy centres and to support state supervision. MATERIALS AND METHODS The audit is realised via mailed TL dosimetry. The TLD system consists of encapsulated LiF:Mg,Ti powder (type MT-N) read with Harshaw manual re...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید