نتایج جستجو برای: TG43U1 MCNP4C
تعداد نتایج: 212 فیلتر نتایج به سال:
The purpose of this study was to estimate the uncertainty in the dose distribution for the (125)I source STM1251, as measured with a radiophotoluminescent glass rod dosimeter and calculated using the Monte Carlo code EGS5 in geometry that included the source structure reported by Kirov et al. This was performed at a range of positions in and on a water phantom 18 cm in diameter and 16 cm in len...
Introduction: 192Ir is one of the important sources frequently used in brachytherapy. Up to now, a lot of commercial models of this source have been made which Ir-192 has been recently added to them. The aim of the present study is to determine the dosimetric parameters of this new source model based on the recommendations of TG-43(U1) protocol using Monte Carlo simulation tech...
A 3D industrial computed tomography (CT) manufactured based on a first generation CT systems, single-source – single-detector, was evaluated. Operation accuracy assessment of the manufactured system was achieved using simulation in comparison with experimental tests. Cs and Co were used as a gamma source. Simulations were achieved using MCNP4C code. Experimental tests of Cs were in good agreeme...
Brachytherapy is a therapeutic approach in which radioactive sources are used to irradiate malignant tumors from near distance. In this study, the comparison of dose distribution in iodine-125 source, STM 1251 and Oncoseed 6711 models was performed using the Monte Carlo Geant4 code. The results obtained from the Monte Carlo calculations have been compared with the TG43U1 formulation and also wi...
The weight window variance reduction method in the general-purpose Monte Carlo N-Particle radiation transport code MCNP has recently been rewritten. In particular, it is now possible to generate weight window importance functions on a superimposed mesh, eliminating the need to subdivide geometries for variance reduction purposes. Our assessment addresses the following questions: (1) Does the n...
In this paper MCNP4C code has been used to simulate of the photonuclear interaction induced by 10MeV electron beam is an approach for generating the high intensity neutrons. Since the results are depended on the target material, the calculations are performed for the targets made of high-z elements of Pb, Ta and W in a simple geometry.
This paper is aimed to investigate the design of an optimized neutron radiography system that utilizes the flux of a reactor. Moderation, collimation aspects are studied. A Monte Carlo code, MCNP4C, was utilized to achieve a maximum and more homogenous neutron flux in the collimator outlet next to the image plane, taking into account geometric characteristics. It was possible to obtain a normal...
کد mcnp4c برای شبیه سازی ریه استفاده شد. در این مطالعه، نارسائی ریه به صورت تئوری بررسی شد. بافت های ریه و نای با استفاده از کد mcnp4c شبیه سازی شد و فرض شد که شامل tc-99m به عنوان چشمه رادیواکتیو با انرژی kev 140 بودند. ما فانتوم ها را تعریف کردیم که یک ریه و یک تومور کروی داشت(ریه چگالی g/cm3 0.296 کد mcnp4c برای شبیه سازی ریه استفاده شد. در این مطالعه، نارسائی ریه به صورت تئوری بررسی شد. باف...
In this paper we propound a nondestructive and noninvasive technique for measuring the thickness of water penetration in a homogeneous slab. The proposed device consists of a 252 Cf spontaneous fission source and a set of 3 He detectors located on the same side of a concrete slab subject to water infiltration. The effectiveness of this technique has been investigated by Monte Carlo simulation...
It is well known that Intercrystal scattering (ICS) and the parallax effect are two major resolution limiting parameters in current PET detector designs with block detectors. More recently for the purpose of resolution recovery, investigators and manufacturers have attempted to accurately model these effects into the image reconstruction task. In this study we utilized the MCNP4C Monte Carlo co...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید