نتایج جستجو برای: Syringe to syringe dispersive liquid phase microextraction
تعداد نتایج: 10850438 فیلتر نتایج به سال:
A novel in-syringe dispersive solid phase extraction (dSPE) system using electrospun silica fibers as adsorbents has been developed in the current work. A few milligrams of electrospun silica fibers were incubated in sample solution in the barrel of a syringe for microextraction assisted by vortex. Due to the benefit of dispersion and the high mass transfer rate of the sub-microscale electrospu...
The application of syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was extended for the separation and preconcentration of trace amounts of cadmium ions from water and cereal samples. The extracted cadmium was quantified by electrothermal atomic absorption spectrometry. Factors affecting the complex formation as well as microextraction efficiency such...
چکیده در بخش اول این پروژه دو روش میکرواستخخرا به نامهای میکرواسخخرا امولسیونی با کمک اموا فراصتتتو 1 و میکرواستتتخخرا مای – مای با کمک هوا 2 ، به عنوان دو روش میکرواستتتخخرا بدون حلال پخشکننده 3 ، برای اسخخرا برخی هیتدروکربتنهای آروماتیتک حلقوی 4 از نمونتههای آبتی بهکار گرفخه و پارامخرهای موثری همچون نوع حلال اسختتتتخرا کننده، حجم حلال اسخخرا کننده، میزان نمک، زمان تابش اموا فراصتو ، تددا...
In this study, a dispersive liquid–liquid microextraction method using an extraction solvent lighter than water has been developed for the extraction and preconcentration of cholecalciferol and calcifediol from plasma samples followed by high performance liquid chromatography determination. Initially, acetonitrile and sodium chloride (NaCl) are added into the plasma as an extraction solvent and...
In this work, a rapid method based on air-assisted liquid liquid microextraction (AALLME) was developed for the determination of three fungicides (azoxystrobin, diethofencarb and pyrimethanil) in water and juice samples. A narrow-neck glass tube was made to facilitate collection of the low-density extractant. The mixture of extractant and sample solution is rapidly sucked into a 5-mL glass syri...
dispersive liquid liquid microextraction (dllme) combined with gas chromatography–mass spectrometry (gc–ms) was used for the extraction and determination of 13 polycyclic aromatic hydrocarbons (pahs) in mineral water samples. in this procedure, the suitable combination of extraction solvent (500 µl chloroform) and disperser solvent (1000 µl acetone) were quickly injected into the water sample (...
novel dispersive liquid-liquid microextraction (dllme), coupled with high performance liquid chromatography with photodiode array detection (hplc-dad) has been applied for the extraction and determination of cyproheptadine (cph), an antihistamine, in human urine samples. in this method, 0.6 ml of acetonitrile (disperser solvent) containing 30 µl of carbon tetrachloride (extraction solvent) was ...
Background: A syringe to syringe dispersive liquid phase micro-extraction-floating organic drop was applied and used for the simultaneous extraction and pre-concentration of trace amounts of amphetamine (AMP) and methamphetamine (MAMP) in urine samples. The extracted analytes were determined by high performance liquid chromatography along with diode array detection. Materials & Methods: In thi...
A simple, rapid and sensitive method was developed for the selective separation and preconcentration of Ni(II) using dispersive liquid-liquid microextraction, by a yellow Schiff's base bisazanyl derivative, as a selective complexing agent. In this method, a mixture of 45 μL chloroform (extraction solvent) and 450 μL tetrahydrofuran (dispersive solvent) is rapidly injected by syringe into a 5 mL...
objective(s): dispersive liquid-liquid microextraction coupled with gas chromatography (gc)-flame ionization detector was developed for the determination of valproic acid (vpa) in human plasma. materials and methods: using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing vpa (ph, 1.0...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید