نتایج جستجو برای: Small field dosimetry

تعداد نتایج: 1519041  

Journal: :iranian journal of medical physics 0
hossein hasani m.sc. student in medical radiation engineering, science and research branch, islamic azad university, tehran, iran hasan nedaie assistant professor, radiotherapy and oncology dept., tehran university of medical sciences, cancer research center, center institute, tehran, iran mohammad hasan zahmatkesh associate professor, medical physics dept., novin medical radiation institute, tehran, iran mahmood allahverdi associate professor, medical physics dept., tehran university of medical sciences, tehran, iran saeid bagheri m.sc. of medical physics, novin medical radiation institute, shahid beheshti university, tehran, iran sajad mirzaie m.sc. student in medical radiation engineering, science and research branch, islamic azad university, tehran, iran

introduction: in radiotherapy, methods of treatment planning are becoming increasingly more complicated. this requires verification of the doses delivered to increasingly smaller and more precise regions. radiotherapy techniques are continuously employing smaller and smaller field sizes to deliver tighter radiation doses with higher therapeutic ratios, generating interest among researchers to p...

Journal: :iranian journal of radiation research 0
m. yarahmadi kurdistan university of medical sciences, sanandaj, iran h.a. nedaie department of medical physics , faculty of medicine, tehran university of medical sciences, tehran, iran m. allahverdi department of medical physics , faculty of medicine, tehran university of medical sciences, tehran, iran kh. asnaashari department of radiotherapy , cancer institute, tehran university of medical sciences, tehran, iran o.a. sauer klinik und poliklinik für strahlentherapie, university of würzburg, josef-schneider-strasse 11, 97080 würzburg, germany

background: small photon fields are increasingly used in modern radiotherapy especially in intensity modulated radiation therapy (imrt) and stereotactic radiosurgery (srs) treatments. accurate beam profile and central axis depth doses measurements of such beams are complicated due to the electron disequilibrium. hence the ebt2 (external beam therapy) gafchromic film was used for dosimetry of sm...

Fariba Eyni Maryam Atarod, Mohammad Javad Tahmasebi Birgani Nahid Chegeni Seyed Mojtaba Hosseini

Introduction: Small field dosimetry is challenging for radiotherapy dosimetry. measurement of the output factor in the air and water (Sc, Scp) is one of the input parameters for commissioning of treatment planning systems and beam modeling. The aims of this study are to measured Sc,Scp for small fields with EBT2 and Ion chamber and design a appropriate mini-phantom for small fi...

Journal: :iranian journal of radiation research 0
w. parwaie department of radiology, faculty of para-medicine, hormozgan university of medical sciences, bandar abbas, iran m. yarahmadi department of medical physics, faculty of medicine, kurdistan university of medical sciences, sanandaj, iran h.a. nedaie department of radiotherapy, cancer institute, tehran university of medical sciences, tehran, iran m.h. zahmatkesh shahid beheshti university of medical sciences, tehran, iran a.h. barati department of medical physics, faculty of medicine, kurdistan university of medical sciences, sanandaj, iran m. afkhami department of radiology, faculty of para-medicine, hormozgan university of medical sciences, bandar abbas, iran

background: accurate small radiation field dosimetry is essential in modern radiotherapy techniques such as stereotactic radiosurgery (srs) and intensity modulated radiotherapy (imrt). precise measurement of dosimetric parameters such as beam profile, percentage depth doses and output factor of these beams are complicated due to the electron disequilibrium and the steep dose gradients. in the p...

Journal: :Japanese Journal of Radiological Technology 1995

A.H. Barati, H.A. Nedaie, M. Afkhami, M. Yarahmadi, M.H. Zahmatkesh, W. Parwaie,

Background: Accurate small radiation field dosimetry is essential in modern radiotherapy techniques such as stereotactic radiosurgery (SRS) and intensity modulated radiotherapy (IMRT). Precise measurement of dosimetric parameters such as beam profile, percentage depth doses and output factor of these beams are complicated due to the electron disequilibrium and the steep dose gradients. In the p...

Hasan Nedaie Hossein Hasani, Mahmood Allahverdi Mohammad Hasan Zahmatkesh Saeid Bagheri Sajad Mirzaie

Introduction: In radiotherapy, methods of treatment planning are becoming increasingly more complicated. This requires verification of the doses delivered to increasingly smaller and more precise regions. Radiotherapy techniques are continuously employing smaller and smaller field sizes to deliver tighter radiation doses with higher therapeutic ratios, generating interest among researchers to p...

J. Novotny Jr., T. Veselsky, V. Pastykova,

Background: To determine the basic physical and dosimetric properties of a new synthetic single-crystal diamond detector and its application for relative small field dosimetry. Materials and Methods: The pre-irradiation dose required to stabilize detector response, dose rate dependence, photon and electron energy dependence, temperature dependence and angular dependence of MicroDiamond detector...

Journal: :journal of biomedical physics and engineering 0
s a rahimi tarbiat modares university b hashemi tarbiat modares university s r mahdavi iran university of medical sciences

background: estimating dosimetric parameters for small fields under non-reference conditions leads to significant errors if done based on conventional protocols used for large fields in reference conditions. hence, further correction factors have been introduced to take into account the influence of spectral quality changes when various detectors are used in non-reference conditions at differen...