نتایج جستجو برای: Silicone tubing

تعداد نتایج: 12203  

Fatemeh Yazdian Khosro Malek Khosravi Mahdi Pesaran Hajiabbas Mohsen Nosrati, Seyed Abbas Shojaosadati,

A dissolved methane sensor based on silicone tube was designed, constructed and optimized.The silicone tube diameter, silicone tube length and helium flow rate (as the carrier gas(were considered as process parameters to be optimized.A continuous stream of helium (50 mL/min) was directed through the tubing, sweeping out the...

Journal: :acta medica iranica 0
"naraghi m tabatabaee mohammadi sz zolfkhani z kashfi a "

endonasal endoscopic laser-assisted dacryocystorhinostomy has many advantages over conventional external dacryocystorhinostomy. this technique avoids a cutaneous scar and causes less surgical trauma and bleeding than that seen in conventional lacrimal surgery. a total of 20 endoscopic laser-assisted dacryocystorhinostomy in 16 patients were performed between 1998 and 1999. the procedure was suc...

2006

Natural plankton assemblages were incubated with a small piece of silicone. Tygon or latex rubber tubing in 200 m1 of culture to determine potential long-term toxic effects of the tubing. Drastic decreases in cell numbers and chlorophyll fluorescence indicated that over 95 "h of the phytoplankton were killed by the latex rubber tubing in 4 d. Even a 1 mm piece of latex tubing lulled -90 % of th...

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2009
fatemeh yazdian seyed abbas shojaosadati mohsen nosrati mahdi pesaran hajiabbas khosro malek khosravi

a dissolved methane sensor based on silicone tube was designed, constructed and optimized.the silicone tube diameter, silicone tube length and helium flow rate (as the carrier gas(were considered as process parameters to be optimized.a continuous stream of helium (50 ml/min) was directed through the tubing, sweeping out the dissolved methane which diffused through the walls of the tubing from t...

1999
M. Kurusz

____________ _ Pump head tubing was studied to determine if internal wear occurred during routine cardiopulmonary bypass. Several segments of silicone rubber tubing were examined in a scanning electron microscope following clinical perfusion. In each case, the proper degree of occlusion had been set just prior to beginning bypass. The roller pump was a six-inch dual roller type, and the tubing ...

Journal: :Aerosol Science and Technology 2009

2009
Michael T. Timko Zhenhong Yu Jesse Kroll John T. Jayne Douglas R. Worsnop Richard C. Miake-Lye Timothy B. Onasch Thomas W. Kirchstetter Hugo Destaillats Amara L. Holder Kevin R. Wilson

Sampling Artifacts from Conductive Silicone Tubing Michael T. Timko a , Zhenhong Yu a , Jesse Kroll a , John T. Jayne a , Douglas R. Worsnop a , Richard C. Miake-Lye a , Timothy B. Onasch a , David Liscinsky b , Thomas W. Kirchstetter c , Hugo Destaillats c , Amara L. Holder d , Jared D. Smith e & Kevin R. Wilson e a Center for Aero-Thermodynamics and Center for Aerosol and Cloud Chemistry , Ae...

Journal: :Journal of lipid research 1971
K Y Lee

14C-labeled oleic acid and (3)H-labeled monoether in a bile salt solution were perfused through three types of plastic tubing. Large proportions of lipid were lost to the walls of silicone rubber and polyvinyl chloride tubes. The major portion of the lipid lost was recoverable only when chloroform-methanol was perfused through the tubings. On the other hand, very little lipid was lost to the wa...

Journal: :The British journal of ophthalmology 1989
W S Grizzard L Allarakhia

Two new disposable cannulas for internal drainage of subretinal fluid are described in this article. We describe a curved and a straight version consisting of plastic hubs, 20 gauge proximal and 25 gauge distal stainless steel hypodermic tubing, and soft and flexible silicone tubing overmounts. Both these cannulas facilitate atraumatic drainage of subretinal fluid through pre-existing retinal h...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید