Medical ultrasound imaging due to close behavior of cancer tumors to body tissues has a low contrast. This problem with synthetic aperture imaging method has been addressed. Although the synthetic aperture imaging technique solved the low-contrast problem of ultrasound images, to an acceptable limit, but the performance of these methods is not even acceptable when the signal to noise ratio (SNR...

Journal: :iranian journal of basic medical sciences 0
shabnam oloomi department of medical physics, mashhad university of medical science, mashhad, iran hadi noori eskandari department of applied mathematics, school of mathematical sciences, ferdowsi university of mashhad, mashhad, iran seyed rasoul zakavi nuclear medicine research center, imam reza hospital, faculty of medicine, mashhad university of medical sciences, mashhad, iran peter knoll department of nuclear medicine wilhelminenspital vienna, austria faraz kalantari research center for nuclear medicine, tehran university of medical sciences, tehran, iran mohsen hajizadeh saffar department of medical physics, mashhad university of medical science, mashhad, iran

objective(s): in spect, the sinogram contains scatter and lack of attenuated counts that degrade the reconstructed image quality and quantity. many techniques for attenuation and scatter correction have been proposed. an acceptable method of correction is to incorporate effects into an iterative statistical reconstruction. here, we propose new maximum likelihood expectation maximization (mlem) ...

Journal: :Journal of Applied Physics 2007

Faraz Kalantari, Hadi Noori Eskandari, Mohsen Hajizadeh Saffar Peter Knoll, Seyed Rasoul Zakavi Shabnam Oloomi

  Objective(s): In SPECT, the sinogram contains scatter and lack of attenuated counts that degrade the reconstructed image quality and quantity. Many techniques for attenuation and scatter correction have been proposed. An acceptable method of correction is to incorporate effects into an iterative statistical reconstruction. Here, we propose new Maximum Likelihood Expectation Maximiz...

Journal: :iranian journal of radiology 0
jian hui gu jiangsu province key laboratory of neuroregeneration, nantong university, nantong, jiangsu, china xue jun zhou department of radiology, affiliated hospital of nantong university, nantong, jiangsu, china dong sheng jin department of radiology, jiangsu province official hospital, nanjing, jiangsu, china wen quan ding department of hand surgery, ningbo no.6 hospital, ningbo university, ningbo, zhejiang, china; department of hand surgery, ningbo no.6 hospital, ningbo university, ningbo, zhejiang, china. tel: +86-18106606963 xin wang department of hand surgery, ningbo no.6 hospital, ningbo university, ningbo, zhejiang, china

conclusion vr reconstruction for both single-direction images and sushi using dti25 raw data provides excellent 3d displays of the peripheral nerves in the wrist region. sushi post-processing is a useful denoising tool because it automatically reduces the majority of isotropic object noise. results single-direction vr reconstruction clearly showed the nerves for both dti6 and dti25 but with obv...

Journal: :international journal of information science and management 0
a. zolghadrasli ph.d., department of electrical engineering, school of engineering, shiraz university

in this paper the author considers a general method, based on time domain samples for spectral manipulation of time limited signals. first, the original signal is divided into some frames in the time domain. then, by presenting a suitable theoretical and computational algorithm, and using a method for improving the speed of convergence, we find the local bandwidth of each frame; thereby, each f...

Journal: :iranian journal of radiology 0
xianchun zeng department of radiology, guizhou provincial people’s hospital, guiyang, china; department of ct, the first affiliated hospital of kunming medical university, kunming, china shaolei kang department of ct, the first affiliated hospital of kunming medical university, kunming, china rongpin wang department of radiology, guizhou provincial people’s hospital, guiyang, china dan han department of ct, the first affiliated hospital of kunming medical university, kunming, china; department of ct, the first affiliated hospital of kunming medical university, kunming, p. o. box: 650032, china. tel: +86-87165324888, fax: +86-87165324888 yong wang department of ct, the first affiliated hospital of kunming medical university, kunming, china shiping yang department of ct, the first affiliated hospital of kunming medical university, kunming, china

conclusion safire reconstruction provided better coronary image quality and displayed the number, morphology, and surrounding lumen of calcium plaques more accurately than traditional fbp reconstruction, with safire3 achieving the best results. results the subjective ratings of image quality using safire1–safire5 reconstructions were significantly higher than those using fbp, with safire3 achie...

Journal: :Calcolo 2021

Abstract In frequency analysis an often appearing problem is the reconstruction of a signal from given samples. Since samples are usually noised, pure interpolating approaches not recommended and appropriate approximation methods more suitable as they can be interpreted kind denoising. Two widely used. One uses reflection coefficients finite sequence Szegő polynomials other one zeros so called ...

Journal: :Applied and Computational Harmonic Analysis 2006