نتایج جستجو برای: Short-circuit (SC) fault

تعداد نتایج: 625656  

Wound-Rotor (WR) resolvers are the most widely used position sensors in applications with harsh environmental conditions. However, their performance is exposed to failure due to the high risk of short circuit (SC) fault. Although the output current of the resolver is negligible, its thin copper wires increase the probability of the short circuit fault. To avoid the propagation of the turn-to-tu...

ژورنال: کنترل 2020

Three phase induction motors have many applications in industries. Consequently, detecting and estimating the fault and compensate it in a way that the faulty induction motor satisfies the predefined goals are important issues. One of the most common faults in induction motors is the short circuit of the stator winding. In this paper, an active fault-tolerant control system is designed and pres...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه صنعتی خواجه نصیرالدین طوسی - دانشکده مهندسی برق و کامپیوتر 1391

power transformers are important equipments in power systems. thus there is a large number of researches devoted of power transformers. however, there is still a demand for future investigations, especially in the field of diagnosis of transformer failures. in order to fulfill the demand, the first part reports a study case in which four main types of failures on the active part are investigate...

In this paper, the effect of number and fault current limiter(FCL) location has been investigated in order to have maximum reduction of short circuit current level in all buses in a real network. To do so, the faulty buses were identified in terms of short circuit current level by computing short circuits on the desired network. Then, while the fault current limit was modeled, its optimal locat...

2017
Puvan Arumugam Tahar Hamiti Christopher Brunson

This paper investigates the behavior of a vectorcontrolled, fault-tolerant, permanent magnet motor drive system adopting a vertically placed strip winding (VSW) which can limit inter-turn short-circuit (SC) fault current to its rated value regardless of the position in the slot containing the shorted turns. The drives’ dynamic behavior is simulated using a per-phase equivalent circuit model wit...

Turn to turn fault is one of the major internal failures in the power transformers that if it is not quickly detected, can be extended and led to a complete transformer breakdown. So, the diagnosis and location of the turn to turn fault of the power transformer, as one of the most important equipment in the power system, is the main objective of this paper. For this purpose, a detailed model of...

Journal: :IEEE Transactions on Industrial Electronics 2021

The temperature evolution during a short-circuit (SC) fault in the dies of three different silicon carbide (SiC) 1200-V power devices is presented this article. Transient electrothermal simulations are performed based on reconstructed structure commercially available devices. reveal location hottest point each device. nonisothermal electrical analysis supports necessity to turn- off SC events r...

2017
Muhammad Shahzad Nazir Qinghua Wu Mengshi Li Luliang Zhang

Considering the importance of perturbations during short circuit (SC) in power conversion devices, this study designed to find out the efficacy of symmetrical short circuit (SSC) of the synchronous generator (SG) and doubly fed induction generators (DFIG). Both wind power systems were separately built (Park’s model) and simulated. Simulation results showed that the DFIG is more efficient, fault...

Power system protection at transmission and distribution levels based on overcurrent relays is essential based on their properties such as detection, stability, high speed, backup and error correction accuracy. Since distributed generation sources are connected to the power grid, they not only increase the short circuit level of the grid, but also disrupt the set point of main and backup relays...

Journal: :journal of sciences, islamic republic of iran 2014
a.d. khalaji

two organic compounds (sc-23=(e)-2-cyano-3-(2,3-dimethoxyphenyl) acrylic acid and sc-25=(e)-2-cyano-3-(2,5-dimethoxyphenyl) acrylic acid) involving methoxy groups as the electron donor and cyanoacrylic acid group as the electron acceptor have been investigated for dye sensitized solar cells. they shows a short-circuit current density (jsc) of 2.08 and 1.81 ma cm-2, an open circuit voltage (voc)...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید