Introduction: Among different non-invasive approaches for determining the stability of the implant within the bone is to use a dynamic device called Periotest®.It is designed to provide objective measurement of tooth mobility. The aim of the present study is to evaluate the stress transfer and stability in short and standard dental implants using Periotest®</sup...
Background and Aims: The aim of this study was to assess the outcome of short implants (<8 mm length) as an alternative to sinus lift surgery and placement of standard-length implants (10-12 mm length) for rehabilitation of atrophic posterior maxilla. Materials and Methods: In this prospective clinical trial, 26 patients with 6-7 mm of residual alveolar bone height in their atrophic posterior ...
Background and purpose: The aim of this study was to investigate the relationship between the implant survival rates and the length and diameter in disabled veterans attending Qazi Tabatabai Dental Clinic, Tehran, Iran during 2000-2010. Materials and methods: A retrospective study was conducted in 181 disabled veterans referring to Qazi Tabatabai Clinic. They received 1,255 implants from thr...
background: the aim of this in vitro study was to evaluate the effect of shape, diameter and length of implants on their primary stability based on resonance frequency analysis. materials and methods: replace select tapered and branemark mk iii implants were selected. each of these two selected groups was divided into nine subgroups based on the implant length (il) (short, medium and long) and ...
Background and Aims: Diferences whithin shape and size of hand wrenches in diferent systems could affect the torque applied. Therefore, evaluation of wrenches has been emphasized. The aim of the present study was to compare the torque values of the long and short torque wrenches in different implant systems including ITI, Implantium and Nobel Biocare. Materials and Methods: In this experimenta...
The aim of this study was to evaluate by photoelastic analysis stress distribution on short and long implants of two dental implant systems with 2-unit implant-supported fixed partial prostheses of 8 mm and 13 mm heights. Sixteen photoelastic models were divided into 4 groups: I: long implant (5 × 11 mm) (Neodent), II: long implant (5 × 11 mm) (Bicon), III: short implant (5 × 6 mm) (Neodent), a...
Short stemmed hip endoprostheses represent a relevant alternative to standard sized total hip stems. Especially in terms of bone stock preservation and minimal invasiveness the reduced length of such implants is beneficial. However, the smaller implant size is linked to a reduced surface geometry and thereby bone-implant-interface to provide implant stability. In order to evaluate the interfaci...
BACKGROUND Research suggests that for individuals with significant low-frequency hearing, implantation of a short-electrode cochlear implant may provide benefits of improved speech perception abilities. Because this strategy combines acoustic and electrical hearing within the same ear while at the same time preserving low-frequency residual acoustic hearing in both ears, localization abilities ...