Sang-Hyo Kim Kun-Soo Kim Do-Hoon Lee Jun-Seung Park Oneil Han

Shear connectors are used in steel beam-concrete slabs of composite frame and bridge structures to transfer shear force according to design loads. The existing Y-type perfobond rib shear connectors are designed for girder slabs of composite bridges. Therefore, the rib and transverse rebars of the conventional Y-type perfobond rib shear connectors are extremely large for the composite frames of ...

Steel-concrete-steel (SCS) sandwich panels are composed of two steel plates with low thicknesses and high densities and strengths and one thick layer between both plates with low strength and density known as core that is composed of concrete. Cohesive material-epoxy resin or shear connectors are usually used to connect the plates to the concrete core. SCS sandwich composites are being develope...

2016
Farzad Tahmasbi Shervin Maleki Mahdi Shariati N. H. Ramli Sulong M. M. Tahir

This paper investigates the behaviour of C-shaped and L-shaped angle shear connectors embedded in solid concrete slabs. An effective finite element model is proposed to simulate the push out tests of these shear connectors that encompass nonlinear material behaviour, large displacement and damage plasticity. The finite element models are validated against test results. Parametric studies using ...

2015
Tingjie Zhang Pengtao Jia

According to the different construction forms of PBL shear connectors in steel-concrete composite beam and steel-concrete joint section, eight finite element models in two groups of the two construction forms are conducted to study different mechanical properties of PBL shear connectors. Following conclusions can be drawn from the finite element method calculation results. The load-slip curve, ...

Journal: :PloS one 2015
Koosha Khorramian Shervin Maleki Mahdi Shariati N H Ramli Sulong

According to recent researches, angle shear connectors are appropriate to transfer longitudinal shear forces across the steel-concrete interface. Angle steel profile has been used in different positions as L-shaped or C-shaped shear connectors. The application of angle shear connectors in tilted positions is of interest in this study. This study investigates the behaviour of tilted-shaped angle...

2017
Qiyun Qiao Wenwen Zhang Zhiwei Qian Wanlin Cao Wenchao Liu

In order to quantitatively evaluate the shear-bearing capacity of shear connectors of square concrete filled steel tube (CFST), push-out tests on 14 square CFSTs with shear connectors have been carried out. Among the 14 CFSTs, there are 13 specimens with steel plate connectors and one specimen with steel bar connectors. The following factors are investigated to figure out their influences on th...

2017
Wen Xue Ju Chen Ji-Hua Zhu

In this study, the effect of corrosion on the static behavior of stud shear connectors was investigated. An innovative test setup for single stud shear connectors was designed and established. Two series of specimens having different stud diameters were fabricated and tested. The test specimens were firstly corroded to different corrosion rates by the electronic accelerating method. Static load...

2012
Ali Shariati N. H. Ramli Mahdi Shariati

This paper evaluates the behavior of channel shear connectors, embedded in a concrete slab, with different concrete materials. The results of a series of limited push-out specimens were presented and discussed. The push-out tests comprise of channel shear connectors in different types of concrete. Reinforcement was included in some specimens, as well. The results showed that using reinforcement...

2010
Qing Quan Liang Brian Uy Howard D. Wright Mark A. Bradford

Steel plates in double skin composite (DSC) panels are restrained by a concrete core and welded stud shear connectors at discrete positions. Local buckling of steel plates in DSC panels may occur in a unilateral mode between stud shear connectors when subjected to combined states of stresses. This paper studies the local and post-local buckling strength of steel plates in DSC panels under biaxi...

Journal: :Nano letters 2009
Hyunhyub Ko Jongho Lee Bryan E Schubert Yu-Lun Chueh Paul W Leu Ronald S Fearing Ali Javey

Conventional connectors utilize mechanical, magnetic, or electrostatic interactions to enable highly specific and reversible binding of the components (i.e., mates) for a wide range of applications. As the connectors are miniaturized to small scales, a number of shortcomings, including low binding strength, high engagement/disengagement energies, difficulties with the engagement, fabrication ch...