نتایج جستجو برای: Shaking amplitude

تعداد نتایج: 99101  

F. Khorsandi, M. Loghavi S. Kamgar,

The aim of this study was to determine the most suitable shaking frequency and amplitude for shake harvesting Esfahan's edible fig (Ficus carica cv. Sabz). A hand held limb shaker with adjustable shaking frequency and amplitude was used for this study. A 3x3 factorial experiment with three levels of oscillating frequency (10, 12 and 14 Hz) and three levels of shaking amplitude (20, 32.5 and 45 ...

Journal: :iran agricultural research 2012
f. khorsandi m. loghavi s. kamgar

the aim of this study was to determine the most suitable shaking frequency and amplitude for shake harvesting esfahan's edible fig (ficus carica cv. sabz). a hand held limb shaker with adjustable shaking frequency and amplitude was used for this study. a 3x3 factorial experiment with three levels of oscillating frequency (10, 12 and 14 hz) and three levels of shaking amplitude (20, 32.5 and 45 ...

ژورنال: علوم آب و خاک 2007
حسین رحیمی, , محمد لغوی, ,

A 4x4 factorial experiment with a completely randomized design with three replications was conducted separately on two major pistachio varieties, Ohady and Kaleghoochy, to investigate the effects of shaking amplitude and frequency on pistachio nut and cluster detachment. Four levels of shaking frequencies used for Ohady were 5, 7.5, 10 and 12.5 Hz, while those of Kaleghoochy were 7.5, 10, 12.5 ...

Journal: :iran agricultural research 2007
m. loghavi sh. mohseni

the aim of this study was to determine the most suitable shaking frequency and amplitude for shake harvesting lime fruit (c. aurantifolia). a tractor mounted limb shaker with adjustable shaking frequency and amplitude, powered by the tractor power-take-off shaft was designed and developed for this study. the rotating input power was transmitted to the shaker flywheel through a multiple sheave v...

M. LOGHAVI SH. MOHSENI

The aim of this study was to determine the most suitable shaking frequency and amplitude for shake harvesting lime fruit (C. aurantifolia). A tractor mounted limb shaker with adjustable shaking frequency and amplitude, powered by the tractor power-take-off shaft was designed and developed for this study. The rotating input power was transmitted to the shaker flywheel through a multiple sheave v...

حسین رحیمی, , محمد لغوی, ,

A 4x4 factorial experiment with a completely randomized design with three replications was conducted separately on two major pistachio varieties, Ohady and Kaleghoochy, to investigate the effects of shaking amplitude and frequency on pistachio nut and cluster detachment. Four levels of shaking frequencies used for Ohady were 5, 7.5, 10 and 12.5 Hz, while those of Kaleghoochy were 7.5, 10, 12.5 ...

Journal: :مهندسی بیوسیستم ایران 0
علی رضایی دانشجوی کارشناسی ارشد گروه مهندسی مکانیک بیوسیستم دانشگاه شیرازاز محمد لغوی استاد گروه مکانیک بیوسیستم دانشگاه شیراز سعادت کامگار استادیار گروه مکانیک بیوسیستم دانشگاه شیراز داریوش زارع دانشیار گروه مکانیک بیوسیستم دانشگاه شیراز

a portable and light pneumatic branch shake system was designed and manufactured in this research for harvesting fruits that can be harvested by shaking branch. required air flow and electric current are provided for operating system from category containing electrical generator and air compressor on wheelbarrows and portable chassis. vibration is equipped by programmable logic controller (plc)...

Journal: :Physical review. E, Statistical, nonlinear, and soft matter physics 2003
Denis Bartolo Armand Ajdari Jean-Baptiste Fournier

The concept of fluctuation-induced effective interactions is extended to systems driven out of equilibrium. We compute the forces experienced by macroscopic objects immersed in a soft material driven by external shaking sources. We show that, in contrast with equilibrium Casimir forces induced by thermal fluctuations, their sign, range, and amplitude depend on specifics of the shaking and can t...

2012
Ulrich Kertzscher Torsten Schneider Leonid Goubergrits Klaus Affeld Daniel Hänggi Andreas Spuler

BACKGROUND Cerebral arterial vasospasm leads to delayed cerebral ischemia and constitutes the major delayed complication following aneurysmal subarachnoid hemorrhage. Cerebral vasospasm can be reduced by increased blood clearance from the subarachnoid space. Clinical pilot studies allow the hypothesis that the clearance of subarachnoid blood is facilitated by means of head shaking. A major obst...

Journal: :Physical review. E, Statistical, nonlinear, and soft matter physics 2014
D P Shinde Anita Mehta G C Barker

We use a hybrid Monte Carlo algorithm to simulate the shaking of spheres at different vibrational amplitudes and find that spontaneous crystallization occurs in specific dynamical regimes. Several crystallizing transitions are typically observed, leading to end states which can be fully or partially ordered, depending on the shaking amplitude, which we investigate using metrics of global and lo...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید