نتایج جستجو برای: Scatter Collimator factor
تعداد نتایج: 857363 فیلتر نتایج به سال:
Introduction: In the last few decades, a lot of monte carlo codes have been introduced for medical applications. this is important because through simulation, we are fully independent of the spectral scattering factor that we are not able measure in real terms. The effect of the radiation energy, the dimension of the radiation field, the sensitive volume of the ion chamber on t...
INTRODUCTION One of the important input factors in the commissioning of the radiotherapy treatment planning systems is the phantom scatter factor (Sp) which requires the same collimator opening for all radiation fields. In this study, we have proposed an analytical method to overcome this issue. METHODS The measurements were performed using Siemens Primus Plus with photon energy 6 MV for fiel...
introduction: image quality and accuracy of in vivo activity quantification in spect are affected by collimator penetration and scatter components, especially in high energy imaging. these phenomena highly depend on the collimator characteristic and photon energy. the presence of penetrated and scattered photons from collimator in spect images degrades spatial resolution, contrast and image qua...
Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...
To more easily estimate accurate values of collimator scatter facor, S(c), we suggest a two-component saturation model that accounts for scatter from the primary collimator and flattening filter and from the collimator jaws. This model, which assumes an exponential distribution of scatter intensity, was tested by in-air measurements using a mini-phantom for 4 MV and 10 MV X-rays of a Clinac 210...
X-ray scatter poses a significant limitation to image quality in cone-beam CT (CBCT), resulting in contrast reduction, image artifacts, and lack of CT number accuracy. We report the performance of a simple scatter correction method in which scatter fluence is estimated directly in each projection from pixel values near the edge of the detector behind the collimator leaves. The algorithm operate...
Accurate determination of the head scatter factor Sc is an important issue, especially for intensity modulated radiation therapy, where the segmented fields are often very irregular and much less than the collimator jaw settings. In this work, we report an Sc calculation algorithm for symmetric, asymmetric, and irregular open fields shaped by the tertiary collimator (a multileaf collimator or b...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید