نتایج جستجو برای: SPECT, Slit Slat collimator

تعداد نتایج: 23367  

Introduction: Myocardial perfusion SPECTby 99mTc-Sestamibi and 99mTc-Tetrofosmin radiopharmaceuticals usually presents a false significant increase in the radiotracer uptake in the inferior myocardium due to the uptake in organs such as liver, bowel, stomach and biliary system. The present study evaluated a suitable Slit angle for differentiating extra-car...

2014
Debora Salvado Kjell Erlandsson Alexandre Bousse Michele Occhipinti Paolo Busca Carlo Fiorini Brian Hutton

The Institute of Nuclear Medicine, University College London, London, UK This project’s goal is to design a SPECT insert for a clinical MRI system for simultaneous brain SPECT/MR imaging. We assume the stationary SPECT insert will consist of two rings of ∼5x5-cm SiPM-based detectors insensitive to magnetic fields, with 0.8-mm intrinsic resolution. The maximum diameter is 44.5 cm, the minimum di...

Journal: :Medical physics 2004
Gengsheng L Zeng Daniel Gagnon

This paper discusses the use of small pixels in a spinning CdZnTe single photon emission computed tomography (SPECT) camera that is mounted with a parallel slat collimator. In a conventional slat collimation configuration, there is a detector pixel between two adjacent collimator slats. In our design, the pixel size is halved. That is, there are two smaller pixels to replace a regular pixel bet...

Journal: :Journal of nuclear medicine technology 2008
Gengsheng L Zeng

UNLABELLED The main objective of this work was the development of a skew-slit collimator for small-animal SPECT to replace the state-of-the-art multipinhole collimator. METHODS A pinhole forms a cone-beam imaging geometry. If the collimator rotates around the object in a circular orbit, the projection measurements acquired by the cone-beam imaging geometry are incomplete and not enough for ar...

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2005
A Kamali-Asl S Sarkar M Shahriari H Agha-Hosseini

Conventional single photon emission computed tomography (SPECT) collimators are not suitable for 511 keV imaging. In order to use a SPECT system for single positron emission tomography (SPET), we need to design high-efficiency collimators capable of absorbing 511 keV photons. Slit slat (SS) collimators have been proposed for this purpose even though the optimization of such collimators has not ...

Journal: :Physics in medicine and biology 2004
Gengsheng L Zheng Daniel Gagnon

In this paper, we propose a CdZnTe rotating and spinning gamma camera attached with a slit collimator. This imaging system acquires convergent planar integrals of a radioactive distribution. Two analytical image reconstruction algorithms are proposed. Preliminary phantom studies show that our small CdZnTe camera with a slit collimator outperforms a larger NaI(Tl) camera with a pinhole collimato...

Journal: :Medical physics 2002
Gengsheng L Zeng Daniel Gagnon Christopher G Matthews Jeffery A Kolthammer Jason D Radachy William G Hawkins

A slat collimator in single photon emission computed tomography consists of a set of parallel slats. As the collimator spins, the detector measures a one-dimensional projection data set. A complete data set can be obtained by rotating the detector/collimator assembly around the object (patient) while the collimator spins continuously. The measured projection data are assumed to be weighted plan...

Journal: :Journal of Nuclear Medicine Technology 2008

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید