نتایج جستجو برای: SP34 slab phantom

تعداد نتایج: 27243  

2017
Om Prakash Gurjar Radha Kishan Paliwal Surendra Prasad Mishra

The aim is to study the density, isodose depths, and doses at different points in slab-pinewood-slab (SPS) phantom, solid phantom SP34 (made up of polystyrene), and chest level of actual patient for developing heterogeneous chest phantom mimicking thoracic region of human body. A 6 MV photon beam of field size of 10 cm × 10 cm was directed perpendicular to the surface of computed tomography (CT...

Introduction: The determination of accurate dose distribution is an issue of fundamental importance in radiotherapy, especially with regard to the fact that the human body is a heterogeneous medium. Therefore, the present study aimed to analyze the density and isodose depth profiles of 6 MV beam in a SP34 slab-wooden dust (pine)-SP34 slab (SWS) heterogeneous phantom.  Materials and Methods: Th...

ژورنال: سنجش و ایمنی پرتو 2015

Neutron response Induced in Thermoluminescence Dosimeter TLD-700 chips due to reactions of thermal neutrons with slab phantom and Badge Dosimeter TLD-600,700 materials in a neutron-gamma mixed field was measured. Using the linear relationship between thermal neutron fluence and the thermal neutrons induced TL response with slab phantom, Badge-TLD Materials, an empirical relationship was introdu...

2000
V. P. SINGH N. M. BADIGER R. R. BIHARI

In the present paper, we estimated backscattering factors for the TLD and active personal dosimeters using 662 keV gamma-ray photons on a PMMA surface, which are, for the TLD, 1.12; Dosicard, 1.116; DRD, 0.99; and Saphydose, 1.073, and on a water slab phantom surface; for the TLD, 1.115; Dosicard, 1.112; DRD, 1; and Saphydose, 1.059. The backscattering factor contribution for the Saphydose is n...

Journal: :Journal of radiological protection : official journal of the Society for Radiological Protection 2012
R Behrens

In the past the operational quantity H(p)(3) has been defined for calibration purposes in a slab phantom. Recently, an additional phantom in the form of a cylinder was suggested for eye lens dosimetry as a cylinder much better approximates the shape of a head than a slab. Therefore, this work investigates whether the quantity H(p)(3), when defined in the respective calibration phantom, adequate...

Journal: :Journal of magnetic resonance imaging : JMRI 2002
Eugene G Kholmovski Andrew L Alexander Dennis L Parker

PURPOSE To improve the imaging efficiency of multi-slab three-dimensional acquisitions by decreasing slab overlap and the number of blanked slices. MATERIALS AND METHODS Application of the histogram matching technique for correction of the slab boundary artifact (SBA) due to non-ideal radiofrequency pulse profiles has been proposed. The technique was validated by studying its effectiveness in...

Ali Jomehzadeh, Alireza Amouheidari Anton Mans Ben Mijnheer Mohammad Mohammadi, Parvaneh Shokrani

Introduction: The use of electronic portal imaging devices (EPIDs) is a method for the dosimetric verification of radiotherapy plans both pretreatment and in-vivo. The aim of this study was to test a 2D EPID-based dosimetry algorithm for dose verification of some plans inside a homogenous and anthropomorphic phantom and in-vivo, as well. Materials and Methods: </strong...

Mehrnoosh Karimipoorfard Sedigheh Sina, Simin MehdizadehNaderi Zahra Molaeimanesh,

Introduction: Nowadays, the demand for CT-scan is increased, and this issue has become a critical subject in radiation protection, because of the risk of cancer especially for children. The quality assurance of CT images is a necessary factor that can effect on children dose. The CT dose index is an important dosimetry index in CT-Scan dosimetry. The purpose of this study is t...

Journal: :iranian journal of radiation research 0
s.b. jia department of physics , ferdowsi university of mashhad, mashhad, iran a.a. mowlavi department of physics , hakim sabzevari university, sabzevar, iran m.h. hadizadeh department of physics , ferdowsi university of mashhad, mashhad, iran m. ebrahimi loushab department of physics , ferdowsi university of mashhad, mashhad, iran

background: the advantages of proton beam in radiation therapy- like small lateral scattering as well as absence of exit dose tail in the organs which are after the tumor- make it capable of delivering more treatment doses to the target and much lesser to the critical tissues near it. materials and methods: in this study, the monte carlo mcnpx code has been used to simulate a slab head phantom ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید