نتایج جستجو برای: SFCL

تعداد نتایج: 180  

2015
Shimin Xue Feng Gao Wenpeng Sun Botong Li

A DC distribution system, which is suitable for access to distributed power generation and DC loads, is one of the development directions in power systems. Furthermore, it could greatly improve the energy efficiency and reduce the loss of power transportation. The huge short circuit current is always a great threat to the safety of the components, especially the capacitors and diodes. A resisti...

2012
Wook - Won Kim Sung - Yul Kim Jin - O Kim

The fault current levels through the electric devices have a significant impact on failure probability. New fault current results in exceeding the rated capacity of circuit breaker and switching equipments and changes operation characteristic of overcurrent relay. In order to solve these problems, SFCL (Superconducting Fault Current Limiter) has rising as one of new alternatives so as to improv...

2018
K. Gopinath C. Baskaran

The Doubly Fed Induction Generator (DFIG) is getting wider popularity due to its ability to adapt with variable wind speed and to capture more wind energy. Though DFIG has a salient feature of the fault ride through capability, this is not sufficient to preserve the necessity of the grid code when the DFIG system is connected with the grid. To accomplish this goal, a DC resistive superconductin...

2015
Rama Rao

In this paper, an application of superconducting fault current limiter (SFCL) is proposed to limit the fault current that occurs in power system, SFCL is a device that uses superconductors to instantaneously limit or reduce unanticipated electrical surges that may occur on utility distribution and transmission networks. Due to the difficulty in power network reinforcement and the interconnectio...

2014
M. Vinoth kannan S. Rajanbabu

As one of the solution of the increase problem of the fault current in a power system, the superconducting fault current limiter (SFCL) has been noticed as the attractive device because it has no power loss in a normal time and can limit the fault current rapidly without additional device to detect the fault current. However, the introduction of the SFCL in a power distribution system affects t...

2017
Gaëtan Didier Charles-Henri Bonnard Thierry Lubin Jean Lévêque G. Didier C. H. Bonnard T. Lubin J. Lévêque

In this paper, authors present a comparative study of inductive and resistive superconducting fault current limiters (SFCL) from current limitation and power system transient stability point of view. Different types of SFCL can be used to decrease the amplitude of fault current in a power system. The two most used are resistive type (rSFCL) and inductive type (iSFCL). However, no studies have b...

2012
G. Vijaya Kumar Prakash Kumar

This paper proposes the possible effect on the reduction of fault current and its protective coordination for upcoming smart grid. Fault levels in electrical distribution system are rising due to the increasing presence of distributed generation, and this rising trend is expected to continue in the future. Superconducting fault current limiter is a promising electrical equipment to reduce the e...

2017
Priyanka R. Patil

Although the introduction of distributed generation (DG) in a distribution system improves the power quality of power system, it increases the fault current level reducing voltage at point of common-coupling (PCC). Hence, there is a need of improving fault ride-through (FRT) capability to avoid sudden tripping of DG units from the utility grid during voltage sag in a faulty condition. In this p...

Journal: :JCM 2014
Lei Chen Hao Pan Changhong Deng Feng Zheng Haijun Yan Fang Guo

Since the interactivity, integrality and instantaneity of information communication in smart substation have been improved to higher levels, it can contribute to promote the realization of a centralized type substation area backup protection (SABP), acting as an integrated protection system for whole substation. On the side, in the case that fault current limiters (FCLs) are suggested to be emp...

2011
Arsalan Hekmati Mehdi Hosseini Mehdi Vakilian Mehdi Fardmanesh

The application of flat superconductor rings has been investigated in the structure of inductive shieldtype high temperature superconducting fault current limiters, HTc-SFCL. A laboratory scale inductive shield-type HTc-SFCL has been designed and fabricated using flat superconductor rings. The fabrication process has been fully presented. YBCO powder has been used for the fabrication of superco...

نمودار تعداد نتایج جستجو در هر سال