نتایج جستجو برای: Resistive and inductive superconductor fault current limiters
تعداد نتایج: 16902794 فیلتر نتایج به سال:
superconductor fault current limiter (sfcl) is an effective device to suppress high fault currents. this paper presents a comparative study of resistive and inductive fault current limiters from transient stability point of view. appropriate location and type of the limiters in a hv substation is selected by a qualitative approach based on the equal area criterion. study system is simulated by...
Superconductor fault current limiter (SFCL) is an effective device to suppress high fault currents. This paper presents a comparative study of resistive and inductive fault current limiters from transient stability point of view. Appropriate location and type of the limiters in a HV substation is selected by a qualitative approach based on the equal area criterion. Study system is simulated by...
One of the worst types of fault that a power system should be designed to withstand is a short circuit. Within the various types of fault current limiters, the superconducting fault current limiter (SFCL) has an extremely fast current limitation. The rapid switching action and the self-sensing nature of the superconductor make SFCLs particularly attractive in fault protection. This very fast ti...
The application of flat superconductor rings has been investigated in the structure of inductive shieldtype high temperature superconducting fault current limiters, HTc-SFCL. A laboratory scale inductive shield-type HTc-SFCL has been designed and fabricated using flat superconductor rings. The fabrication process has been fully presented. YBCO powder has been used for the fabrication of superco...
The design process of a superconducting current limiter (SFCL) requires simulation and definition of its electrical, magnetic and thermal properties in form of equivalent circuits and mathematical models. However, any change in SFCL parameters: dimension, resistance, and operating temperature can affect the limiting mode, quench time, and restore time. In this paper, following the simulation of...
In this paper, authors present a comparative study of inductive and resistive superconducting fault current limiters (SFCL) from current limitation and power system transient stability point of view. Different types of SFCL can be used to decrease the amplitude of fault current in a power system. The two most used are resistive type (rSFCL) and inductive type (iSFCL). However, no studies have b...
This paper presents the analysis, design, construction and ac test results of low voltage single-phase resistive superconductor electrical current limiters. Two different types of resistive superconductor current limiter are presented: the first one is built with three concentric, cylindrical and helicoidal coils connected in parallel and the second one is built with two superposed cylindrical ...
An approach for assignment of the optimal location and tap changer adjustment related to flux-lock type superconducting fault current limiters with tap changer (TC-FLSFCL) is used in this paper by debating the reduction of fault current flowing from each device and enhancement of reliability varying with customer type in a distribution network connected with distribution generation (DG). TC-FLS...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید