نتایج جستجو برای: Radiotherapy Planning Computer-Assisted

تعداد نتایج: 923795  

Introduction: Computerized treatment planning is a rapidly evolving modality that depends on hardware and software efficiency. Despite ICRU recommendations suggesting 5% deviation in dose delivery the overall uncertainty shall be less than 3.5% as suggested by B.J. Minjnheer. J. In house spreadsheets are developed by the medical physicists to cross-verify the dose calculated by the Treatment Pl...

F Shahedi, H Gholamhosseinian M H Bahreyni M Mohammadi, M Momennezhad, R Salek, S Bayani, S M Hashemi, S Nasseri

Background: The present study aimed to introduce a rapid transmission dosimetry through an electronic portal-imaging device (EPID) to achieve two-dimensional (2D) dose distribution for homogenous environments. Material and Methods: In this Phantom study, first, the EPID calibration curve and correction coefficients for field size were obtained from EPID and ionization chamber. Second, the...

A Nainggolan S A Pawiro,

Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...

Journal: :Turkish neurosurgery 2014
Cahit Kural Yusuf Emrah Eyi

We congratulate the authors for reporting their results. Ege et al. have shared their results that they got from the fluoroscopy device retrospectively. We think that this study method could not prove the exact amount of radiation exposure that impacts the surgical team correctly. The authors compare their study with similar studies (2, 3) that measure radiation exposure by dosimetry as more ob...

2004
Angelo Zizzari

This paper describes a supporting tool for medical doctors, providing the automatic definition of radiation volumes (planning target volume, PTV) for conformal radiotherapy computed on detected tumor areas (gross tumor volume, GTV) within radiographic images. First, the recognized brain tumor is geometrically reconstructed and visualized in three-dimensional space. Then, the respective growth d...

Journal: :Physics in medicine and biology 2012
Amandine Le Maitre Mathieu Hatt Olivier Pradier Catherine Cheze-le Rest Dimitris Visvikis

Over the past few years several automatic and semi-automatic PET segmentation methods for target volume definition in radiotherapy have been proposed. The objective of this study is to compare different methods in terms of dosimetry. For such a comparison, a gold standard is needed. For this purpose, realistic GATE-simulated PET images were used. Three lung cases and three H&N cases were design...

Introduction: Treatment planning is the most important part of treatment. One of the important entries into treatment planning systems is the beam dose distribution data which maybe typically measured or calculated in a long time. This study aimed at shortening the time of dose calculations using artificial neural network (ANN) and finding the best method of training t...

2007
M. Pantic A. Djordjevic H. Koppelaar

Automated Study Planning (ASP) system was designed to assist the students in organising their studies. Interactive expert system ASP forms a part of a bigger project that concerns computer-based education and training in higher learning [1]. The formulation of the study-planning process, whereupon the reasoning engine of ASP is built, has been acquired from the practical knowledge of the study-...

2005
Mehran R. Zaini Gary J. Forest David D. Loshek

We have automated the determination of the placement location of the dosimetry ion chamber within intensity-modulated radiotherapy (IMRT) fields, as part of streamlining the entire IMRT quality assurance process. This paper describes the mathematical image-processing techniques to arrive at the appropriate measurement locations within the planar dose maps of the IMRT fields. A specific spot wit...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید