نتایج جستجو برای: RC Columns

تعداد نتایج: 35361  

ژورنال: مواد پرانرژی 2019

Evaluation and Comparison of Behavior of Steel Jacketed RC Columns with Circular and Square Sections under Blast Loading Reinforced concrete (RC) structures are widely used in urban buildings and infrastructures, and these are always subjected to explosions caused by intentional or unintentional accidents. Among the structural members, columns are key load carrier elements. In this paper, b...

Journal: :international journal of civil engineering 0
guray arslan insaat fak. davutpasa kampus 34220 esenler-istanbul/turkiye melih hacisalihoglu insaat fak. davutpasa kampus 34220 esenler-istanbul/turkiye muzaffer balci insaat fak. davutpasa kampus 34220 esenler-istanbul/turkiye muzaffer borekci insaat fak. davutpasa kampus 34220 esenler-istanbul/turkiye

the main cause of structural damage in buildings subjected to seismic actions is lateral drift. in almost all reinforced concrete (rc) structures, whether designed with walls or frames, it is likely to be the code drift limits that control the design drift. the design drift limits and their contribution to damage may be represented indirectly through the material strain limits. the aim of this ...

2015
Mostafa Osman

Since columns are the most important elements of the structures, failure of one column in a critical location can cause a progressive collapse. In this respect, the repair and strengthening of columns is a very important subject to reduce the building failure and to keep the columns capacity. Twenty columns with different parameters is tested and analysis. Eleven typical confined reinforced con...

2014
M. Rizwan M. T. A. Chaudhary M. Ilyas

The cyclic tests of the columns are of practical relevance to the performance of compression members during earthquake loading. The strength, ductility and energy absorption capabilities of RC columns, subjected to cyclic loading, have been estimated by many researchers. These characteristics are not normally inherent in plain concrete but can be achieved by effectively confining columns throug...

2012
T. Jiang

An important application of fiber-reinforced polymer (FRP) composites is to provide confinement to reinforced concrete (RC) columns to enhance their loadcarrying capacity. However, this application is generally restricted to short columns as existing design guidelines do not contain provisions for the design of FRP jackets for slender columns. This situation has been due to both the scarcity of...

2002
Jung-Yoon Lee Young-Jun Oh Ji-Sun Park Mohamad Y. Mansour

Concrete columns confined with high-strength fiber reinforced polymer (FRP) composites can enhance the strength as well as the ductility of such structures. In recent years, the use of FRP composites to repair and strengthen existing reinforced concrete (RC) structures has been widely used. When the columns of existing RC structures are wrapped with FRP composites, the core concrete of such col...

2011
Shuichi Fujikura

This paper reports the findings of research examining the blast resistance of bridge piers that are designed in accordance with current knowledge and specifications to ensure ductile seismic performance. Blast testing was conducted on 1/4 scale ductile RC columns, and nonductile RC columns retrofitted with steel jacketing. The seismically designed RC and steel jacketed RC columns did not exhibi...

2017
Qingwei Chen Hailong Zhao Tiecheng Wang

Original scientific paper RC frame structures with specially shaped columns and RC frame structures with rectangular columns are different types of structures with different column sections. A progressive collapse analysis model of RC frames was proposed using the beam-column element and joint element based on the program OpenSees. Progressive collapse performance of the experimental frame was ...

2016
Omar I. Abdelkarim Mohamed A. ElGawady

This paper presents the difference in behavior between hollow-core fiber reinforced polymer-concrete-steel (HC-FCS) columns and conventional reinforced concrete (RC) columns under vehicle collision in terms of dynamic and static forces. The HC-FCS column consisted of an outer FRP tube, an inner steel tube, and a concrete shell sandwiched between the two tubes. The steel tube was hollow inside a...

2012
X. Zeng B. Xu

In this study, experimental study on six RC columns with different slenderness ratios under axial rapid loading was conducted to investigate the axial compression behaviour of RC columns considering the effect of strain rates. The failure pattern of the specimens and the relations of axial loading versus the axial deformation were described. From the test results, the specimens under static and...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید