نتایج جستجو برای: Pulse Oximetry signal

تعداد نتایج: 499341  

Journal: :journal of biomedical physics and engineering 0
m. a. younessi heravi m. a. khalilzadeh s. joharinia

background: one of the main problems especially in operating room and monitoring devices is measurement of blood pressure (bp) by sphygmomanometer cuff. objective: in this study we designed a new method to measure bp changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. this will be achieved by extraction of the time difference...

J. G. Webster, R. P. Buinevicius,

Pulse oximetry measures the relative concentration of arterial oxygenated hemoglobin and reduced hemoglobin. This paper presents the design of a pulse oximeter, which measures the presence of a third substance, carboxyhemoglobin (HbCO), by unfiltered LEDs at 660 nm, 810 nm, and 940 nm. Background information is given on the theory of pulse oximetry. Theoretical approximations and calculations w...

Journal: :مهندسی برق و الکترونیک ایران 0
r. p. buinevicius r. p. buinevicius j. g. webster

pulse oximetry measures the relative concentration of arterial oxygenated hemoglobin and reduced hemoglobin. this paper presents the design of a pulse oximeter, which measures the presence of a third substance, carboxyhemoglobin (hbco), by unfiltered leds at 660 nm, 810 nm, and 940 nm. background information is given on the theory of pulse oximetry. theoretical approximations and calculations w...

Journal: :Journal of Clinical Sleep Medicine 2018

Journal: :Critical Care 2005
Xavier Monnet Bouchra Lamia Jean-Louis Teboul

The pulse oximetry plethysmographic signal resembles the peripheral arterial pressure waveform, and the degree of respiratory variation in the pulse oximetry wave is close to the degree of respiratory arterial pulse pressure variation. Thus, it is tempting to speculate that pulse oximetry can be used to assess preload responsiveness in mechanically ventilated patients. In this commentary we bri...

Behnam Sobouti, Hossain Ghjaeimi, Nasrin Khalesi, Nastaran Khosravi, Samira khani, Yaser Ghavami,

Background: Pulse Oximeter monitoring has become so common over previous decades that in some health care units, blood oxygen level is now considered as the fifth vital sign. However, it seems there is still some lack of knowledge and/or experience among medical staff operating pulse oximeter and interpreting its results. The aim of this study was to investigate and compare the knowledge on Pul...

Behnam Sobouti, Nasrin Khalesi, Nastaran Khosravi, Samira khani, Yaser Ghavami,

Background: Pulse Oximeter monitoring has become so common over previous decades that in some health care units, blood oxygen level is now considered as the fifth vital sign. However, it seems there is still some lack of knowledge and/or experience among medical staff operating pulse oximeter and interpreting its results. The aim of this study was to investigate and compare the knowledge on Pul...

Background: Congenital heart diseases, which are asymptomatic at birth, are the most important causes of infant mortality. This study aimed to evaluate the role of pulse oximetry in the early detection of congenital heart diseases among newborns.Methods: In this cross-sectional descriptive study, 1230 newborns who were born in university hospitals in an urban area of Iran were placed unde...

Journal: :dental research journal 0
n. kaviani r. birang

introduction inhalation sedation is used for pain and anxiety control in dentistry. hypoxia is the most important side effect which can be detected using pulse oximetry, however, there are different opinions about the use of this instrument. this study has been designed to investigate this subject. methods and materials in this study, 32 adult patients from periodontal surgical department were ...

Journal: :nursing practice today 0
parisa moradi majd paramedical faculty, department of anesthesia, school of allied medical sciences, iran university of medical science, tehran, iran. mitra zolfaghari department of e-learning in medical education, virtual school and nursing and midwifery care research center, tehran university of medical sciences, tehran, iran. fatemeh behesht aeen department of critical care, school of nursing and midwifery, tehran university of medical science, tehran, iran. alireza mohseni paramedical faculty, department of laboratory sciences, school of allied medical sciences, mazandaran university of medical science, sari, iran. khadijeh azimi department of critical care, school of nursing and midwifery, tehran university of medical science, tehran, iran. hamid haghani department of biostatistics, school of management and information technology, tehran university of medical sciences, tehran, iran.

background & aim : pulse oximetry is a frequently used and standard non-invasive method for monitoring oxygen (o2)-saturation in blood. many factors including dark skin and pigmentation may effect on rate of saturation of the blood oxygen absorbed by pulse oximetry. the effect of nail polish and/or henna color on blood oxygen has not been yet identified and the present study has been carried ou...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید