نتایج جستجو برای: Pulse Height Distributions
تعداد نتایج: 320960 فیلتر نتایج به سال:
Introduction: Unfolding X-ray spectrum is a powerful tool for quality control of X-ray tubes. Generally, the acquisition of the X-ray spectrum in diagnostic radiology departments is complicated and difficult due to high photon flux. Measurement of x ray spectra using radiation detectors could not be performed accurately, because of the pulse pile up. Therefore, indirect methods...
We present new results on neutron and gamma-ray pulse-height distributions (PHDs) measured with liquid scintillators from five plutonium-oxide samples of varying mass and burnup and a Cf isotopic source. We show that the analysis of the pulse-height distributions can be used to easily distinguish the fissile material (plutonium oxide) from the Cf source. Moreover, the slope of the measured puls...
The EGS4 Monte Carlo simulation technique was used to obtain the energy spectra of photons arriving at a detector from the pulse height distributions measured by the same detector. First, the measured pulse height distribution for incident photons from several radiation sources such as 60Co, 137Cs, 152Eu and 207Bi with a collimator are compared with those calculated using the EGS4 code to inves...
Previous work (Ahn and Liu (1990) J. Aerosol. Sci. 21, 249—261; Brockmann (1981) Ph.D. Thesis, University of Minnesota; Rebours et al. (1992) J. Aerosol. Sci. 23, S189—S192; Stolzenburg (1988) Ph.D. thesis, University of Minnesota) has shown that for particles smaller than about 15 nm, pulse heights produced by the optical detector in a white-light ultrafine condensation nucleus counter (UCNC; ...
We describe the use of the MCNP-PoliMi code to simulate, on an event-by-event basis, the detection of neutrons by organic scintillators. This code keeps track of single neutron interactions, including the collision nucleus, the energy deposited, and the time distribution of collision events. We show that the total pulse-height response is given by the sum of many possible neutron histories, eac...
We have investigated the response of an argon-methane proportional counter to monochromatic X-rays in the range 99-277 eV . The apparent nonlinearities in mean pulse height as a function of photon energy and the detailed shape of the pulse height distribution for each energy can be predicted quite precisely using the extensive atomic data available for argon. Based on this understanding, we pro...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید