نتایج جستجو برای: Position calibration
تعداد نتایج: 293035 فیلتر نتایج به سال:
OBJECTIVE To compare two methods of respiratory inductive plethysmography (RIP) calibration in three different positions. METHODS We evaluated 28 healthy subjects (18 women and 10 men), with a mean age of 25.4 ± 3.9 years. For all of the subjects, isovolume maneuver calibration (ISOCAL) and qualitative diagnostic calibration (QDC) were used in the orthostatic, sitting, and supine positions. I...
Abstract The Mingantu Spectral Radioheliograph (MUSER), a new generation of solar dedicated radio imaging-spectroscopic telescope, has realized high-time, high-angular, and high-frequency resolution imaging the Sun over an ultra-broadband frequency range. Each pair MUSER antennas measures complex visibility in aperture plane for each integration time channel. corresponding image channel is then...
A method of module calibration and image processing based on a measurement system for 3-D foot shapes is described, which contains a module calibration system for the compensation of different position errors. A double scanning process with a calibration frame structure is performed, realizing thus a mapping conversion between the two coordinate systems. With the feature points formed by the in...
Conventional freehand 3D ultrasound (US) is a complex process, involving calibration, scanning, processing, volume reconstruction, and visualization. Prior to calibration, a position sensor is attached to the probe for tagging each image with its position and orientation in space; then calibration process is performed to determine the spatial transformation of the scan plan with respect to the ...
The basic requirement for the BEPC beam position monitor is the measurement of the beam orbit with 0.1 mm precision near the collision point. To improve the measurement accuracy, the response of the beam position monitor pickups was mapped in the laboratory before they were installed in the BEPC ring. The microcomputer-controlled test set consists of high frequency coaxial switches to select ea...
A common practice when carrying out self-calibration of a camera from one or more views is to start with a guess at the principal point. The general belief is that inaccuracies in the estimation of the principal point do not have a significant effect on the other calibration parameters. It is the purpose of this paper to refute that belief. Indeed, it is demonstrated that the determination of t...
A new calibration method for industrial robot system calibration on a manufacturing floor is presented in this paper. To calibrate the robot system, a laser sensor to measure the distance between robot tool and measurement surface is attached to the robot end-effector and a grid is established in the floor. Given two position command pulses for a robot manipulator and using the position differe...
In the applications of parallel manipulators, kinematic calibration is required to eliminate the errors resulting from the manufacturing and assembly of both base and tools. In this paper, a calibration method of base and tool transformation is developed by virtue of optical position sensors. An error model for calibration is constructed using differential geometry method. The pose error is obt...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید