نتایج جستجو برای: Porous bone implant

تعداد نتایج: 387661  

Journal: :The Journal of bone and joint surgery. British volume 2001
M J Coathup G W Blunn N Flynn C Williams N P Thomas

We investigated the implant-bone interface around one design of femoral stem, proximally coated with either a plasma-sprayed porous coating (plain porous) or a hydroxyapatite porous coating (porous HA), or which had been grit-blasted (Interlok). Of 165 patients implanted with a Bimetric hip hemiarthroplasty (Biomet, Bridgend, UK) specimens were retrieved from 58 at post-mortem. We estimated ing...

2016
Xiaojun Weng Hailin Yang Jian Xu Xiaosheng Li Qiande Liao Jing Wang

The aim of the present study was to observe the performance of Ti-25Nb alloys with various porosities as femoral stem prostheses in a rabbit model, thus providing basic experimental evidence for the development of porous prostheses. The porous Ti-25Nb alloy prostheses were designed according to the morphology of the medullary cavity. These prostheses were placed into the femoral medullary cavit...

Journal: :Journal of orthopaedic research : official publication of the Orthopaedic Research Society 2017
Sajad Arabnejad Burnett Johnston Michael Tanzer Damiano Pasini

Current hip replacement femoral implants are made of fully solid materials which all have stiffness considerably higher than that of bone. This mechanical mismatch can cause significant bone resorption secondary to stress shielding, which can lead to serious complications such as peri-prosthetic fracture during or after revision surgery. In this work, a high strength fully porous material with ...

Journal: :The International journal of oral & maxillofacial implants 2015
Jin Whan Lee Hai Bo Wen Suneel Battula Rama Akella Michael Collins Georgios E Romanos

PURPOSE This study evaluated the stability and histologic proof of osseoincorporation of Trabecular Metal (TM) dental implants, which feature a tantalum-based porous midsection. MATERIALS AND METHODS A total of 48 TM implants (test group) and Tapered Screw-Vent implants (control group) were immediately placed bilaterally into mandibular extraction sockets in dogs. Resonance frequency analysis...

Journal: :Journal of medical and dental sciences 2008
Akio Tsuchiya Shinichi Sotome Yoshinori Asou Masanori Kikuchi Yoshihisa Koyama Tetsuro Ogawa Junzo Tanaka Kenichi Shinomiya

A porous hydroxyapatite/collagen composite (HAp/Col) was developed that consists of hydroxyapatite nanocrystals and atelocollagen. In this study, cylindrical (diameter: 5 mm, height: 3 mm) porous HAp/Col implants with different pore sizes (diameter: 160 or 290 microm) were prepared, and the influences of pore size and implanted volume were evaluated using a rabbit bone defect model. In the impl...

Journal: :Journal of neurosurgery 1994
W T Couldwell T C Chen M H Weiss T Fukushima W Dougherty

The authors describe the use of a porous polyethylene Flexblock implant for cosmetic cranioplasty. The implant may be used to cover any small- or medium-sized (< 8 cm) cranial defect, offering similar cosmetic results to standard alloplast cranioplasty while decreasing operation time. The porous implant design permits ingrowth of soft tissue and bone to increase implant strength and decrease th...

Journal: :Journal of biomedical materials research 1999
C A Simmons N Valiquette R M Pilliar

The osseointegration and long-term success of bone-interfacing implants are dependent on mechanical stability of the implant relative to host bone during the early healing period. The geometric design of an implant surface may play an important role in affecting early implant stabilization, possibly by influencing tissue healing dynamics. In this study, we compared the early tissue healing resp...

2006
Aline Scalone Brentel Luana Marotta Reis de Vasconcellos Marize Varella Oliveira Mário Lima de Alencastro Graça Luis Gustavo Oliveira de Vasconcellos Carlos Alberto Alves Cairo Yasmin Rodarte Carvalho

The purpose of this study was to analyze the bone repair around commercially pure titanium implants with rough and porous surface, fabricated using powder metallurgy technique, after their insertion in tibiae of rabbits. Seven male rabbits were used. Each animal received 3 porous-surface implants in the left tibia and 3 rough-surface implants in the right tibia. The rabbits were sacrificed 4 we...

2011
Xinming Guo Muwan Chen Wenzhou Feng Jiabi Liang Huibin Zhao Lin Tian Hui Chao Xuenong Zou

Many studies in recent years have focused on surface engineering of implant materials in order to improve their biocompatibility and other performance. Porous tantalum implants have increasingly been used in implant surgeries, due to their biocompatibility, physical stability, and good mechanical strength. In this study we functionalized the porous tantalum implant for sustained drug delivery c...

Journal: :ACS applied materials & interfaces 2016
Peng Xiu Zhaojun Jia Jia Lv Chuan Yin Yan Cheng Ke Zhang Chunli Song Huijie Leng Yufeng Zheng Hong Cai Zhongjun Liu

3D printed porous titanium (Ti) holds enormous potential for load-bearing orthopedic applications. Although the 3D printing technique has good control over the macro-sturctures of porous Ti, the surface properties that affect tissue response are beyond its control, adding the need for tailored surface treatment to improve its osseointegration capacity. Here, the one step microarc oxidation (MAO...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید