نتایج جستجو برای: Planar imaging
تعداد نتایج: 511276 فیلتر نتایج به سال:
introduction: despite widespread use of 67gallium for lymphoma evaluation, timing of imaging after injection is a matter of controversy and to the extent of our knowledge no direct comparison has been made between early and delayed gallium images. we aimed to compare 24 and 48 hours post injection planar gallium imaging for evaluation of lymphoma recurrence. methods: 255 patients suspicious of...
introduction: the limited resolution of the imaging system causes partial volume effects (pves). these results in spreading of image counts to the neighboring pixels. this phenomenon is called spill-out effect. this study aimed at quantifying pves using imagej. methods:technetium-99m solution of concentration of 74 kbq/ml was filled into spheres a, b and c of diameters: 26 mm, 20 mm and 16 mm r...
Introduction: Although PET scanning using F-18[FDG] is considered the superior radiotracer for tumnor imaging, Gallium-67 is still in use for some malignancies such as lymphoma and hepatoma. One of the strategies to improve the diagnostic accuracy of Gallium is to perform SPECT which is reported to be more sensitive compared to planar imaging. In this study we compa...
introduction echo-planar imaging (epi) is a group of fast data acquisition methods commonly used in fmri studies. it acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. a well-known problem with epi is that it is more sensitive to distortions due to the used encoding scheme. source of distortion is inhomogeneity in the static b0 field that ...
introduction: although pet scanning using f-18[fdg] is considered the superior radiotracer for tumnor imaging, gallium-67 is still in use for some malignancies such as lymphoma and hepatoma. one of the strategies to improve the diagnostic accuracy of gallium is to perform spect which is reported to be more sensitive compared to planar imaging. in this study we compared the sensitivity of spect ...
Metastatic survey of the patients with known primary malignancies with bone scan is one of the most common studies in nuclear medicine. Unfortunately the conventional planar bone scan has a very low specificity for differentiating benign from malignant lesions especially in the spinal column. In this study, we compared the specificity of SPECT imaging and convention...
Objective(s): In this study, we aimed to analyze the relationship between the diagnostic ability of fused single photon emission computed tomography/computed tomography (SPECT/CT) images in localization of parathyroid lesions and the size of adenomas or hyperplastic glands. Methods: Five patients with primary hyperparathyroidism (PHPT) and 4 patients with secondary hyperparathyroidism (SHPT) we...
metastatic survey of the patients with known primary malignancies with bone scan is one of the most common studies in nuclear medicine. unfortunately the conventional planar bone scan has a very low specificity for differentiating benign from malignant lesions especially in the spinal column. in this study, we compared the specificity of spect imaging and conventional planar bone scan. we studi...
Objective(s): To investigate and compare quantitative accuracy of kidney absorbed dose measures made from both 2D and 3D imaging in patients receiving 177LuDOTATATE (Lutate) for treatment of neuroendocrine tumours (NETs). Methods: Patients receiving Lutate therapy underwent both whole body planar imaging and SPECT/CT imaging over the kidneys at time points 0.5, 4, 24, and 96-120 hours after inj...
Background & Aims: Spatial resolution is one of the important features of evaluating the function of nuclear medicine imaging systems. The aim of this study was evaluating the capability of the spatial resolution in images of nuclear medicine planar by calculating the modulation transfer function (MTF). Materials & Methods: Nuclear medicine imaging of capillary tube with activity 1 mCi was per...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید