Journal: :iranian journal of medical physics 0
mohammad taghi bahreyni toossi professor, medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iran jalil pirayesh islamian assistant professor, medical physics dept., faculty of medicine, tabriz university of medical sciences, tabriz, iran mahdi momennezhad assistant professor, nuclear medicine dept., imam reza hospital, mashhad university of medical sciences, mashhad, iran seyed rasoul zakavi associate professor, nuclear medicine dept., imam reza hospital, mashhad university of medical sciences, mashhad, iran ramin sadeghi assistant professor, nuclear medicine dept., imam reza hospital, mashhad university of medical sciences, mashhad, iran lejonberg m professor, medical radiation physics dept., clinical sciences-lund, lund university, lund, sweden

introduction: in single photon emission computed tomography (spect), the projection data used for image reconstruction are distorted by several factors, including attenuation and scattering of gamma rays, collimator structure, data acquisition method, organ motion, and washout of radiopharmaceuticals. all these make reconstruction of a quantitative spect image very difficult. simulation of a sp...

Journal: :iranian journal of medical physics 0
jalil pirayesh islamian department of medical physics, tabriz university of medical sciences, tabriz, iran. mohammad taghi bahreyni toossi department of medical physics, mashhad university of medical sciences, mashhad, iran.

introduction quality control is an important phenomenon in nuclear medicine imaging. a jaszczak spect phantom provides consistent performance information for any spect or pet system. this article describes the simulation of a jaszczak phantom and creating an executable phantom file for comparing assessment of spect cameras using simind monte carlo simulation program which is well-established fo...

Jalil Pirayesh Islamian, Mehdi Momennezhad Michael Ljungberg Mohammad Taghi Bahreyni Toossi, Shahrokh Naseri

Introduction Quality control is an important phenomenon in nuclear medicine imaging. A Jaszczak SPECT Phantom provides consistent performance information for any SPECT or PET system. This article describes the simulation of a Jaszczak phantom and creating an executable phantom file for comparing assessment of SPECT cameras using SIMIND Monte Carlo simulation program which is well-established fo...

Journal: :iranian journal of radiation research 0
m.r. teimoori sichani department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran m. amoui department of nuclear medicine, shahid beheshti university of medical science, tehran, iran sh. akhlaghpoor noor medical imaging center, tehran, iran m. hosntalab department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran

background: in this study, quantitative 32p bremsstrahlung planar and spect imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate dosimetry in clinical practice. materials and methods: ct, planar and spect bremsstrahlung images of jaszczak phantom containing a known activity of 32p were acquired. in addition, phanto...

M. Amoui, M. Hosntalab, M.R. Teimoori Sichani, Sh. Akhlaghpoor,

Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...

Asghar Hadadi, Farshid babapoor Mofrad Jalil Pirayesh Islamian, Mohammad Khoshakhlagh Sedigheh Jafari

Introduction: Acquiring a high quality image has assigned an important concern for obtaining accurate diagnosis in nuclear medicine. Detector and collimator are critical component of Single Photon Emission Computed Tomography (SPECT) imaging system for giving accurate information from exact pattern of radionuclide distribution in the target organ. The images are strongly affect...

Nazila Shahmari Payvand Taherparvar

Introduction: Treatment efficacy of radiation therapy using Yttrium-90 radionuclide is evaluated by the bremsstrahlung SPECT imaging following radiation therapy. The radioisotopic images have the ability to provide reliable activity map of 90Y distribution. But these images have a low quantitative accuracy in the 90Y bremsstrahlung SPECT imaging, therefore the optimization of...

2011
J. M. Warwick S. Rubow M. du Toit E. Beetge P. Carey P. Dupont

Purpose. Striatal single photon emission computed tomography (SPECT) imaging of the dopaminergic system is becoming increasingly used for clinical and research studies. The question about the value of nonuniform attenuation correction has become more relevant with the increasing availability of hybrid SPECT-CT scanners. In this study, the value of nonuniform attenuation correction and correctio...

Journal: :iranian journal of nuclear medicine 2011
faraz kalantari hossein rajabi mohsen saghari alireza emami ardekani

introduction: monte carlo (mc) is the most common method for simulating virtual spect projections. it is useful for optimizing procedures, evaluating correction algorithms and more recently image reconstruction as a forward projector in iterative algorithms; however, the main drawback of mc is its long run time. we introduced a model based method considering the effect of body attenuation and i...

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...