نتایج جستجو برای: Perchlorate-selective electrode

تعداد نتایج: 263113  

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2010
mohammad mazloum-ardakani roya mazidi mohammad hossein mashhadizadeh hossein naeimi kobra rabiei

in this work we introduce a practical use of synthesized schiff base metal complex in sensing application. a new perchlorate-selective electrode based on the complex n, n'-4-nitro-phenylmethanebis-(salicylaldiminato) copper (ii) [cul] as the membrane carrier was developed. the electrode exhibits a good  nernstian slope of -55.0 ± 1.0 mv/decade and a linear range of  for perchlorate. the limit o...

Hossein Naeimi Kobra Rabiei Mohammad Hossein Mashhadizadeh Mohammad Mazloum-Ardakani, Roya Mazidi

In this work we introduce a practical use of synthesized Schiff base metal complex in sensing application. A new perchlorate-selective electrode based on the complex N, N'-4-nitro-phenylmethanebis-(salicylaldiminato) copper (II) [CuL] as the membrane carrier was developed. The electrode exhibits a good  Nernstian slope of -55.0 ± 1.0 mV/decade and a linear range of  for perchlorate. The lim...

Journal: :Analytical chemistry 2008
Yushin Kim Shigeru Amemiya

A highly sensitive analytical method is required for the assessment of nanomolar perchlorate contamination in drinking water as an emerging environmental problem. We developed the novel approach based on a voltammetric ion-selective electrode to enable the electrochemical detection of "redox-inactive" perchlorate at a nanomolar level without its electrolysis. The perchlorate-selective electrode...

Journal: :Journal of hazardous materials 2009
Behzad Rezaei Soraia Meghdadi Saeid Bagherpour

A synthesized bis(dibenzoylmethanato)Co(II) complex (Co(DBM)(2)), has been used as a ionophore for the preparation of a new perchlorate ion-selective electrode. The electrode exhibits a Nernstian response over the perchlorate concentration range of 8.0x10(-7)-1.0x10(-1)M with a slope of 60.3+/-0.5 mV per decade of concentration. The limit of detection as determined from the intersection of the ...

2006
María Jesús Segui Josefa Lizondo-Sabater Ramon Martínez-Máñez Félix Sancenon Juan Soto Eduardo Garcia-Breijo Luis Gil

The ionophore 1,4,7,10,13-penta(n-octyl)-1,4,7,10,13-pentaazacyclopentadecane (L) was used for the development of miniaturised perchlorate-selective electrodes in thickfilm technology. Different PVC membranes containing L and the plasticizers o-nitrophenyl octyl ether (NPOE), dibutyl phthalate (DBP), bis(2-ethylhexyl)sebacate (DOS) and dibutyl sebacate (DBS) were prepared and placed on a graphi...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه شیراز - دانشکده علوم 1390

a novel silver (ag) nanocomposite electrode was proposed that fabricated from metal nanostructures and ionic liquids. the combined application of unique properties of nanomaterials and ionic liquids in the design of this ag nanocomposite results in electrodes with interesting advantages compared to the conventional metal disk electrode. in the first part of this thesis, the elecrocatalytic eff...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه رازی - دانشکده علوم 1389

fluorescence chemical sensors for the highly sensitive and selective determination of pb2+ , hg2+, co2+ and fe3+ ions in aqueous solutions are described. the ion sensing system was prepared by incorporating lipophilic ligand (l) as a neutral ion-selective fluoroionophore in the plasticized pvc membrane containing sodium tetraphenylborate or potasium tetrakis (p-chlorophenyl) borate as a liphoph...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه صنعتی اصفهان - دانشکده شیمی 1390

abstract venlafaxine, 1–[2–(dimethylamino)–1–(4–methoxyphenyl) ethyl]cyclohexanol hydrochloride is a novel non-tricyclic antidepressant. venlafaxine is a second generation antidepressant drug, has a neuropharmacologic profile distinct from that of existing antidepressants including tricyclic compounds, selective serotonin reuptake inhibitors and monoamine oxidase inhibitors. venlafaxine impart...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2003
Demet Kuruoğlu Esin Canel Shahabuddin Memon Mustafa Yilmaz Esma Kiliç

A hydrogen ion-selective poly(vinyl chloride) membrane electrode was constructed using 5,11,17,23-tetra-tert-butyl-25,26,27,28-tetracyanomethoxycalix[4]arene as a neutral carrier. The electrode showed an apparent Nernstian response in the 2-11.5 pH range with a slope of 54.0 +/- 0.2 mV/pH at 20 +/- degrees C. This electrode showed a rapid response of the emf to changes in the pH, high ion selec...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید