نتایج جستجو برای: Patient motion

تعداد نتایج: 914097  

Journal: :iranian journal of nuclear medicine 2004
seyed rasoul zakavi mohsen hajizadeh amin zonoozi mehdi momennezhad kamran aryana

introduction: motion of the patient during myocardial perfusion spect could potentially results in false perfusion defects. the effect of different reconstruction methods on these artifacts is not studied. clarification of the relation between the extent, severity and duration of motion with the resultant artifacts may be helpful in designing special soft wares for motion correction. this study...

پایان نامه :دانشگاه آزاد اسلامی - دانشگاه آزاد اسلامی واحد تهران مرکزی - دانشکده هنر و معماری 1393

" استاپ موشن" (stop motion) یا انیمیشن ایست – حرکتی یکی از تکنیک های ساخت انیمیشن که در آن با استفاده از فیلمبرداری فریم به فریم اشیاء فیزیکی را به حرکت در می آورند و از پشت سر هم قراردادن تصاویر این حرکت های فریم به فریم، تصور حرکت القا می شود. "موشن گرافیک" (motion graphic) نیز یکی دیگر از تکنیک های ساخت انیمیشن است. این تکنیک با استفاده از تکنولوژی ویدئو و با ایجاد توهم حرکت یا تغییر در ظاهر...

Journal: :iranian journal of radiation research 0
a. esmaili torshabi medical physics group, department of electrical and computer engineering, graduate university of advanced technology, haftbagh st. 7631133131, kerman, iran

background: in radiation treatment of moving targets located in thorax region of patient body, the delivered dose does not match with the planned treatment, resulting in some over and under dosage in the tumor volume, as a function of motion magnitude and frequency. several efforts have been done to investigate the target motion effects on dose distribution in the target and surrounding normal ...

B. Hu, H. W. Zhang, Y. L. Wang,

Background: A method to track liver tumor motion signals from fluoroscopic images without any implanted gold fiducial markers was proposed in this study to overcome the adverse effects on precise tumor irradiation caused by respiratory movement. Materials and Methods: The method was based on the following idea: (i) Before treatment, a series of fluoroscopic images corresponding to different bre...

Journal: :iranian journal of nuclear medicine 2005
arman rahmim

with the arrival of increasingly higher resolution pet systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. in this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. for the first type of motion...

Arman Rahmim

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...

Journal: :iranian journal of radiation research 0
h. w. zhang department of radiotherapy; jiang-xi cancer hospital; nanchang 330029, china y. l. wang department of radiation oncology, pla general hospital, beijing 100853, china y. l. wang department of radiation oncology, pla general hospital, beijing 100853, china

background: a method to track liver tumor motion signals from fluoroscopic images without any implanted gold fiducial markers was proposed in this study to overcome the adverse effects on precise tumor irradiation caused by respiratory movement. materials and methods: the method was based on the following idea: (i) before treatment, a series of fluoroscopic images corresponding to different bre...

Journal: :iranian journal of radiation research 0
m. zehtabian medical radiation department and medical imaging research center, school of engineering, shiraz university, shiraz, iran r. faghihi medical radiation department and medical imaging research center, school of engineering, shiraz university, shiraz, iran m.a. mosleh-shirazi center for research in medical physics and biomedical engineering and physics unit, radiotherapy department, namazi hospital, shiraz university of medical sciences, shiraz, iran a.r. shakibafard radiology department, shiraz university of medical sciences, shiraz, iran m. mohammadi medical physics department, royal adelaide hospital, adelaide, australia m. baradaran-ghahfarokhi medical physics and medical engineering department, school of medicine, isfahan university of medical sciences, isfahan, iran

background: the aim of this work was to study the feasibility of constructing a fast thorax model suitable for simulating lung motion due to respiration using only one ct dataset. materials and methods: for each of six patients with different thorax sizes, two sets of ct images were obtained in single-breath-hold inhale and exhale stages in the supine position. the ct images were then analyzed ...

Background: in radiation treatment of moving targets located in thorax region of patient body, the delivered dose does not match with the planned treatment, resulting in some over and under dosage in the tumor volume, as a function of motion magnitude and frequency. Several efforts have been done to investigate the target motion effects on dose distribution in the target and surrounding normal ...

رجبی, حسین, شیرازی, علیرضا , صادقی, مهدی, محمدی, ایرج, پولادیان, مجید ,

Background and purpose: Patient motion during myocardial perfusion SPECT can produce artifacts in reconstructed images which might affect clinical diagnosis. This paper attempts to present a new approach for the detection and correction of cardiac motion utilizing the data obtained during the imaging process. Materials and methods: Our method quantifies motion through polynomial curves modelin...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید