نتایج جستجو برای: PVC-based membrane
تعداد نتایج: 3283838 فیلتر نتایج به سال:
a pvc-based membrane containing cerium phosphate was developed. unlike the cerium phosphate itself that acts as a cation exchanger, the membrane exhibited anion-exchange properties. therefore, the utility of this compound as a sensory element for detection of molybdate ions was pursued. the response of molybdate selective electrode based on this membrane was perfectly linear in the concentratio...
For spectrophotometric analysis of Hg (II) ions, we have used and compared two membranes preparation methods using different polymer; one is poly(vinyl chloride) (PVC) and the other is triacetylcellulose (TAC). In the case of TAC membrane, it was treated with a ligand solution (1.166 × 10-3 mole L-1) in ethylenediamine at the ambient temperature for almost 2-5 min. However, in the case of PVC m...
sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of vo2+ in aqueous solutions. the sol-gel and pvcmembrane electrodes exhibited linear response with nernstian slopes of 29.3 and 28.4 mv perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...
Sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of VO2+ in aqueous solutions. The sol-gel and PVCmembrane electrodes exhibited linear response with Nernstian slopes of 29.3 and 28.4 mV perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...
A PVC-based membrane containing cerium phosphate was developed. Unlike the cerium phosphate itself that acts as a cation exchanger, the membrane exhibited anion-exchange properties. Therefore, the utility of this compound as a sensory element for detection of molybdate ions was pursued. The response of molybdate selective electrode based on this membrane was perfectly linear in the concentr...
in this work, a novel zr02+ pvc-based membrane sensor based on 4,7,13,16,21,24-hexa oxa-1,10- diazabicyclo[8,8,8]- hexa cosane (hodbhc) as a new ionophore is presented. the sensor displays a linear dynamic rangebetween 1.0x 10-1 and 1.0x10 6 m, with a near nernstian slope of 29.9 ± 0.4 mv per decade in an acidic solution(ph=1). the limit of detection is 8.0 x 1 0 7 m. the electrodes possess adv...
in this work, novel thin film composite membranes (tfcs) of poly (ether-6-block amide) (pebax-1657) on a polyvinyl chloride (pvc) ultrafiltration membrane as support were prepared using inclined coating method for co2 separation. investigating the effects of top selective layer thickness formed by controlling the coating angle (15-60°) and polymer solution concentration (5-10 wt.%), and also, t...
two poly(oxyethylene) derivatives 1.10-bis(2'-benzoic acid)-1,4,7,1-tetradecane (l1) and 1,7-bis(2'-benzoic acid)-1,4,7-trioxaheptane (l2) were used as suitable ionophores for the preparation of potassium-selective pvc-membrane electrodes. the resulting electrodes based on l1 and l2 exhibit linear responses to the activity of k+ ions within the concentration ranges of 3.1´10-5 -2.7´10-2 m and 2...
Clomipramine hydrochloride, active component of an antidepressant drug, was determined in the pharmaceutical formulation by two kinds of potentiometric sensor; a PVC membrane sensor and a carbon paste electrode modified by MWCNTs and ionic liquid. Both sensors were corporated with clomipramine-tetraphenylborate ion-pair complex and they respond based on ion exchange mechanism. The best PVC memb...
نمودار تعداد نتایج جستجو در هر سال