نتایج جستجو برای: Nonlinear Static Analysis

تعداد نتایج: 3060140  

Journal: :civil engineering infrastructures journal 0
seyed mehdi zahrai associate professor, center of excellence for engineering and management of civil infrastructures, school of civil engineering, college of engineering, university of tehran, p.o.box: 11155-4563, tehran, iran. alireza ezoddin ph.d. student, faculty of civil engineering, university of semnan, semnan, iran.

progressive collapse is a chain reaction of failures propagating throughout a portion of the structure disproportionate to the original local failure occurring when a sudden loss of a critical load‐bearing element initiates a structural element failure, eventually resulting in partial or full collapse of the structure. both general services administration (gsa) and united states department of d...

Journal: :international journal of civil engineering 0
m. mahmoudi shahid rajaee teacher training university t. teimoori shahid rajaee teacher training university h. kozani shahid rajaee teacher training university

the current building codes provide limited prescriptive guidance on design for protection of buildings due to progressive collapse. progressive collapse is a situation in which a localized failure in a structure, caused by an abnormal load, such as explosions or other happenings. three procedures, often employed for determination of the structural response during progressive collapse i.e. linea...

Journal: :international journal of civil engineering 0
f.r. rofooei civil engineering department, sharif university of technology, tehran, iran, m. r. mirjalili doctoral student, structural engineering, civil engineering department, sharif university of technology, tehran, iran n. k. a. attari department of structural engineering, building and housing research center (bhrc), tehran, iran

the nonlinear static procedures (nsps) proposed by design codes do not lead to reliable results especially for tall buildings. they generally provide inconsistent estimates of inelastic seismic demands, especially for the top floors due to their inabilities in considering the higher modes effects. in this paper, a new enhanced pushover procedure is proposed which is based on the envelope of the...

Journal: :international journal of civil engineering 0
e. wahyuni civil engineering department, campus its sukolilo, surabaya 60111, east java, indonesia y. tethool civil engineering department, campus its sukolilo, surabaya 60111, east java, indonesia

the purpose of this study is to determine the effect of vierendeel panel width and vertical truss spacing ratio in an inelastic behavior of the stf system due to earthquake loads. the stf system is applied to a six-storey building that serves as apartments [2]. the stf system is used in the building in the transverse direction (n-s direction), while in the longitudinal direction (w-e direction)...

Journal: :journal of the structural engineering and geotechnics 0
araliya mosleh department of civil eng., faculty of engineering, university of aveiro, 3810-193 aveiro, portugal. hamed hamidi department of civil eng., babol noshirvani university of technology, iran ahmad nicknamc department of civil eng., iran university of science&technology, p.o. box 16765-163, tehran, iran josé jara department of civil eng., faculty of engineering, universidad michoacana de san nicolas de hidalgo, morelia, mexico humberto varume construct-lese, department of civil eng., faculty of engineering, university of porto, 4200-465 porto, portugal

bridges, as an essential part of transportation system, play a special role in economy, politic and military all around the world. serviceability of bridges is of high importance especially in emergencies, helping injured people and proportioning transportation after earthquakes. earthquake regulation codes, normally suggest linear methods to conduct the analysis, and nonlinear analysis is bare...

Journal: :civil engineering infrastructures journal 0
seyed bahram beheshti-aval associate professor, civil engineering faculty, k.n. toosi university of technology, tehran, iran ehsan jahanfekr ph.d. candidate, faculty of technical and engineering, hormozgan university, bandarabas, iran

displacement coefficient method (dcm) stipulated in the asce 41-06 standard is becoming the preferred method for seismic rehabilitation of buildings in many high-seismic-hazard countries. applications of the method for non-building constructions such as bridges are beyond the scope of this standard. thus its application to this kind of structure should be approached with care. target displaceme...

Journal: :civil engineering infrastructures journal 0
mussa mahmoudi shahid rajaee teacher training university seyed mohammad reza mortazavi shahid rajaee teacher training university saeid ajdari shahid rajaee teacher training university

response modification factor (r factor) is one of the seismic design parameters to be considered in evaluating the performance of buildings during strong motions. this paper has tried to evaluate the response modification factor of concrete coupled shear wall structures with various length/depth ratios of spandrel beams. the effect of diagonal reinforcement of spandrel beam was also evaluated o...

In the present paper, the focus is on the evaluation of steel dual-system frame buildings using four main types of structural analysis (Linear Static, Linear Dynamic, Nonlinear Static and Nonlinear Dynamic Analyses) with regard to "Seismic Rehabilitation Code for Existing Buildings in Iran" (based on FEMA 273 and 356) where the first two authors of the article tend to follow the previous work (...

پایان نامه :دانشگاه بین المللی امام خمینی (ره) - قزوین - دانشکده علوم پایه 1390

بررسی وجود و چندگانگی جوابهای معادلات دیفرانسیل به ویژه با شرایط مرزی اغلب بسی دشوار بوده و همراه با گام های ملالت آور می باشد بطوریکه همواره نیاز به پیش شرط هایی می باشد که معادلات دیفرانسیل با شرایط مرزی مورد نظر باید داشته باشد. بنابراین اثبات آنالیزی وجود و چندگانگی جوابهای مسائل مقدار مرزی غیر خطی اغلب غیر ممکن می باشد. روشهای تقریبی- تحلیلی یا روشهای عددی صرفاً برای بدست آوردن جواب موجود ...

Journal: :مهندسی عمران فردوسی 0
مجتبی رضوی محمدرضا شیدایی

zipper braced frames are an innovative bracing system for steel structures. conventional inverted-v-braced frames exhibit a design problem arising from the unbalanced vertical force generated by the lower story braces when one of them buckles. this adverse effect can be mitigated by adding zipper columns or vertical members connecting the intersection points of the braces above the first floor....