نتایج جستجو برای: Moment Resisting

تعداد نتایج: 64231  

Moment resisting frames as one of the conventional lateral load resisting systems in buildings suffer from some limitations including code limitations on minimum span-to-depth ratio to ensure the formation of plastic hinges with adequate length at beam ends. According to seismic codes, in ordinary steel moment resisting frames the minimum span-to-depth ratios should be limited to 5 and in speci...

Journal: :international journal of civil engineering 0
mehdi mahdavi adeli faculty of civil eng., 424, hafez ave., tehran, iran, 15914 mehdi banazadeh no. 510, faculty of civil eng., 424, hafez ave., tehran, iran, 15914 ardeshir deylami no. 606, faculty of civil eng., 424, hafez ave., tehran, iran, 15914

the objective of this paper is to determine the drift demand hazard curves of steel moment-resisting frames with different number of stories in territory of tehran this is done through the combination of the results obtained from probabilistic seismic hazard analysis and the demand estimated through the best probabilistic seismic demand models. to select the best demand model, in this paper, a ...

Following the Northridge earthquake of 1994, a significant number of steel moment resisting structural systems were damaged. Several studies have been conducted to improve the seismic performance of steel structures and specially their beam-to-column connections. One of the proposed connections for special moment-resisting frames included AISC-358 is Kaiser bolted bracket moment connection, bri...

Precast concrete structures in Iran are generally designed as continuous columns with hinged beams, thereby making them simple frames. In this system in site show walls in two directions of buildings guaranteed lateral resisting system. However, in order to obtain a seismic resisting frame, the connection between beam and column should be moment resisting and ductile, allowing the formation of ...

2017
David Cassiano Carlos Rebelo Luís Simoes da Silva

Nowadays, many buildings with steel Moment Resisting Frames (MRF) are built in seismic zones when seismic codes are at its early stages of development, and as such, these structures are often designed solely to resist lateral wind loads without providing an overall ductile mechanism. On the other hand, current seismic design criteria based on hierarchy of resistance allow enhancing the structur...

2002
Rakesh K. Goel Anil K. Chopra

Most seismic codes specify empirical formulas to estimate the fundamental vibration period of buildings. Evaluated first in this paper are the formulas specified in present US codes using the available data on the fundamental period of buildings “measured” from their motions recorded during eight California earthquakes, starting from the 1971 San Fernando earthquake and ending with the 1994 Nor...

Journal: :International Journal for Research in Applied Science and Engineering Technology 2017

2008
Rama Raju Nagesh. R. Iyer

ABSTRACT:The design of structures subjected to natural hazards such as earthquakes and typhoons demands safety of structures which is governed by the natural frequencies and the amount of damping in each mode of vibration. Fundamental frequency of a building and its damping have a remarkable effect on the magnitude of its response. The ability to predict these characteristics at the design stag...

2000

This paper describes an experimental investigation into the use of steel bars bonded into glulam timber beams with epoxy resins in order to provide moment-resisting joints between glulam beams and steel supports. The objective of this research was to provide information about the bending and shear strength of such connections. Past research has investigated the use of steel rods epoxy bonded in...

Journal: :مهندسی عمران فردوسی 0
فرهاد شهیدی امام جمعه فریبرز ناطقی الهی مهران سید رزاقی فرهود شهیدی امام جمعه

in the aftermath of the 1994 northridge, california, earthquake. a significant number of steel moment resisting structural systems were damaged. many studies and researches have been conducted to improve the seismic performance of structures after the catastrophe. one of the proposed connections for special moment-resisting frames included aisc-358 is kaiser bolted bracket moment connection, br...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید