نتایج جستجو برای: Modular Stem
تعداد نتایج: 323525 فیلتر نتایج به سال:
Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...
a modular $k$-coloring, $kge 2,$ of a graph $g$ without isolated vertices is a coloring of the vertices of $g$ with the elements in $mathbb{z}_k$ having the property that for every two adjacent vertices of $g,$ the sums of the colors of the neighbors are different in $mathbb{z}_k.$ the minimum $k$ for which $g$ has a modular $k-$coloring is the modular chromatic number of $g.$ except for some s...
BACKGROUND Mechanical failure of femoral stems at the modular junction of revision hip arthroplasty systems has been reported only infrequently. In the current study, the cause of six stem fractures, which occurred in vivo, was analyzed with use of clinical data and failure analysis. METHODS Six patients with a fracture at the mid-stem junction of a modular revision hip implant were identifie...
Due to their theoretical advantages, hip systems combining modular necks and large diameter femoral heads have gradually gained popularity. However, among others, concerns regarding changes in the load transfer patterns were raised. Recent stress analyses have indeed shown that the use of modular necks and big femoral heads causes significant changes in the strain distribution along the femur. ...
BACKGROUND AND PURPOSE Due to the relative lack of reports on the medium- to long-term clinical and radiographic results of modular femoral cementless revision, we conducted this study to evaluate the medium- to long-term results of uncemented femoral stem revisions using the modular MRP-TITAN stem with distal diaphyseal fixation in a consecutive patient series. PATIENTS AND METHODS We retros...
To the Editor of the SICOT-J Orthopaedic Journal, I am writing to you as I would like to kindly express some considerations on the case-report of Dr. Marco Ceretti on ‘‘Modular titanium alloy neck failure in total hip replacement’’ published in your on-line journal last April (M. Ceretti and F. Falez SICOT J 2016, 2, 20). The Authors report on ‘‘a case of a repetitive modular femoral neck prost...
Thirty-five total hip arthroplasties (33 patients) were performed in cases of Crowe grade III or IV hip dysplasia using subtrochanteric shortening osteotomy with two kinds of femoral stem: monoblock and modular type. All acetabular components were used with a cementless cup. The average patient age was 47.8 years, and the average follow-up time was 5.1 years. Acetabular reconstruction was perfo...
Due to the known potential for fretting and corrosion at modular junctions in orthopaedic implants, this retrospective study evaluated radiographic and clinical outcomes of 85 primary TKA patients implanted with modular stemmed tibial components and followed up for an average of 82 months. There was low incidence of tibial radiolucent lines, excellent functional outcomes, and no complications a...
Novel concept of a modular hip implant could contribute to less implant failure in THA: a hypothesis
Background The modularity in total hip arthroplasty (THA) allows orthopaedic surgeons for an exact reconstruction of hip biomechanical parameters especially in revision and tumor arthroplasty. Modular structured femoral stems using taper junctions showed increased implant breakage in the recent past. Presentation of the hypothesis We hypothesize that a novel modular stem-neck-interface leads ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید