نتایج جستجو برای: Megavoltage Energy

تعداد نتایج: 666708  

2005
W. Strydom W. Parker M. Olivares

Megavoltage electron beams represent an important treatment modality in modern radiotherapy, often providing a unique option in the treatment of superficial tumours (less than 5 cm deep). Electrons have been used in radiotherapy since the early 1950s, first produced by betatrons and then by microtrons and linacs. Modern high energy linacs typically provide, in addition to two megavoltage photon...

2016
Grace Tang Christopher Moussot Daniel Morf Edward Seppi Howard Amols

Most of the treatment units, both new and old models, are equipped with a megavoltage portal imager but its use for volumetric imaging is limited. This is mainly due to the poor image quality produced by the high-energy treatment beam (> 6MV). A linac at our center is equipped with a prototype 2.5 MV imaging beam. This study evaluates the feasibility of low-dose megavoltage cone-beam imaging wi...

2009
Sean Zhang Praimakorn Liengsawangwong Patricia Lindsay Karl Prado Tzouh–Liang Sun Roy Steadham Xiaochun Wang Mohammad R. Salehpour Michael Gillin

Modern dual photon energy linear accelerators often come with a few megavoltage electron beams. The megavoltage electron beam has limited range and relative sharp distal falloff in its depth dose curve compared to that of megavoltage photon beam. Its radiation dose is often delivered appositionally to cover the target volume to its distal 90% depth dose (d90), while avoiding the normal--sometim...

Journal: :iranian journal of medical physics 0
rezvan khaldari medical physics department, medical school, tabriz university of medical sciences, tabriz, iran asghar mesbahi medical physics department, medical school, tabriz university of medical sciences, tabriz, iran. umit kara suleyman demirel university

introduction: globally, the need for radiotherapy as a part of cancer management increases every year. thus, the shielding for megavoltage radiotherapy rooms is of great importance. materials and methods: in the present study, 14 types of developed high-density concrete with densities ranging from 2.45 to 5.11 were simulated by using monte carlo method. the linear attenuation coefficient and th...

Journal: :Medical physics 2003
John Balog Gustavo Olivera Jeff Kapatoes

Helical tomotherapy presented many unique dosimetric challenges and solutions during the initial commissioning process, and some of them are presented. The dose calculation algorithm is convolution/superposition based. This requires that the energy fluence spectrum and magnitude be quantified. The methodology for doing so is described. Aspects of the energy fluence characterization that are uni...

2005
S. Sundar C. Deehan

Background: The in vitro studies show that the modern cardiac pacemakers utilising the complementary metal-oxide semi-conductor (CMOS) circuitry can be adversely affected by therapeutic radiation. However, the published clinical data are sparse regarding the safety of radiotherapy delivery to patients with artificial pacemakers. Despite the potential risk of life threatening complications, ther...

Journal: :Medical physics 2006
Martin J Butson Tsang Cheung Peter K N Yu

Gafchromic XRCT, radiochromic film is assessed over a broad energy range, from kilovoltage to megavoltage x rays for variations in reflected optical density to dose response. A large energy dependence was found with reflected optical density output for the same delivered dose varying from 7.8±0.35 at 25.5keV (50kVp) peaking at 12.1±0.5 at 54keV (125kVp) to 0.975±0.03 at 2300keV (10MV) when norm...

Introduction: Globally, the need for radiotherapy as a part of cancer management increases every year. Thus, the shielding for megavoltage radiotherapy rooms is of great importance. Materials and Methods: In the present study, 14 types of developed high-density concrete with densities ranging from 2.45 to 5.11 were simulated by using Monte Carlo method. The linear attenuation coefficient and t...

Journal: :Medical physics 2009
Chester S Reft

Optically stimulated luminescent detectors, which are widely used in radiation protection, offer a number of potential advantages for application in radiation therapy dosimetry. Their introduction into this field has been somewhat hampered by the lack of information on their radiation response in megavoltage beams. Here the response of a commercially available optically stimulated luminescent d...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید