نتایج جستجو برای: MIPO

تعداد نتایج: 146  

2013
Min Li Xu Zhang Xu Liu Yang Jing

Minimally invasive plate osteosynthesis (MIPO), which is developed under the guidance of biological osteosynthesis (BO) rules, can achieve faster and better rehabilitation. MIPO is mainly used in long bone fractures such as humerus, tibia and femur, but the technique is distinctive in each fracture site. The operative method, experimental outcome and comparison with other internal fixation meth...

Journal: :Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES 2016
Deniz Gülabi Halil İbrahim Bekler Fevzi Sağlam Zeki Taşdemir Gültekin Sıtkı Çeçen Nurzat Elmalı

BACKGROUND Treatment of the distal tibial fractures are challenging due to the limited soft tissue, subcutaneous location and poor vascularity. In this control-matched study, it was aimed to compare the traditional open reduction and internal fixation with minimal invasive plating (MIPO). We hypothesized that superior results may be achieved with MIPO technique. METHODS 22 patients treated wi...

Journal: :Research in developmental disabilities 2011
Jenny Gibson Jamilla Hussain Samina Holsgrove Catherine Adams Jonathan Green

Direct observation of peer relating is potentially a sensitive and ecologically valid measure of child social functioning, but there has been a lack of standardised methods. The Manchester Inventory for Playground Observation (MIPO) was developed as a practical yet rigorous assessment of this kind for 5-11 year olds. We report on the initial reliability and validity of the MIPO and its ability ...

2017
Shekhar P. Malve Nitish Arora Sunil G. Kulkarni Harshit Gehlot Mallikarjun Deepak Garg

Background: We compared the clinical, radiological and functional outcome of extra-articular distal tibia fractures treated with Minimal invasive plate osteosynthesis (MIPO) and intramedullary nailing (IMN) Methods: A prospective study included 51 patients (IMN-25 patients, MIPO-26 patients). Two groups were compared for mean operative time, mean hospital stay, mean healing time, complications,...

2016
Zichao Xue Haitao Xu Haoliang Ding Hui Qin Zhiquan An

Minimally invasive plate osteosynthesis (MIPO) has been widely accepted because of its satisfactory clinical outcomes. However, the implant construct that works best for MIPO remains controversial. Different plate designs result in different influence mechanisms to blood flow. In this study, we created ulnar fractures in 42 beagle dogs and fixed the fractures using MIPO. The dogs were randomly ...

Journal: :Orthopedics 2014
Jun-Gyu Moon Hyuk-Nam Kwon Sandeep Biraris Won-Yong Shon

Minimally invasive plate osteosynthesis (MIPO) has been used for humeral shaft fractures, but concerns exist about soft tissue injuries. The purpose of this study was to report the surgical technique and clinical outcomes of MIPO using a helical plate for metadiaphyseal complex humeral shaft fractures. Twelve patients with acute displacement involving proximal and middle third humeral shaft fra...

2015
Tatsuji Fujiwara

Introduction Recently, the technique of minimally invasive plate osteosynthesis (MIPO) can also be applied to volar locking plates in distal radius fractures. The advantages of MIPO are fracture healing, a quick return to activities of daily life, and cosmetics as a result of the preservation of the soft tissue compared with conventional plate osteosynthesis. The purpose of the present study wa...

2016
Hao Qiu Zhihui Wei Yuting Liu Jing Dong Xin Zhou Liangjun Yin Minhua Zhang Minpeng Lu

BACKGROUND The optimal surgical procedure for humeral shaft fractures remains a matter of debate. We aimed to establish the optimum procedure by performing a Bayesian network meta-analysis. METHODS PubMed, EMBASE, the Cochrane Library, and Medline were searched for both randomized controlled trials and prospective studies of surgical treatment for humeral shaft fractures. The quality of the i...

Journal: :Clinics in podiatric medicine and surgery 2018
Ted C Lai Justin J Fleming

Surgical treatment of distal tibia fractures can present as a difficult task. Intramedullary nailing (IMN), external fixation, and open reduction internal fixation (ORIF) have displayed various complications ranging from a high rate of knee morbidity with IMN to wound complications and infection with ORIF. Minimally invasive plate osteosynthesis (MIPO) has been used to decrease development of t...

2014
Tao Lin Baojun Xiao Xiucai Ma Dehao Fu Shuhua Yang

BACKGROUND The use of minimally invasive plate osteosynthesis (MIPO) via anterolateral deltoid splitting has good outcomes in the management of proximal humerus fractures. While using this approach has several advantages, including minimal soft tissue disruption, preservation of natural biology and minimal blood loss, there is an increased risk for axillary nerve damage. This study compared the...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید